-
- Emily Jane Woo.
- US Food and Drug Administration, HFM-222, 1401 Rockville Pike, Rockville, MD 20852, USA. jane.woo@fda.hhs.gov
- Spine J. 2012 Oct 1;12(10):894-9.
Background ContextAdverse effects of recombinant human bone morphogenetic protein-2 (rhBMP-2) in spinal surgery have previously been observed. However, because of its size, scope, and nature, the US Food and Drug Administration's database of postmarketing reports is useful for detecting new and unexpected safety concerns.PurposeTo characterize adverse events reported to the FDA; to characterize off-label use of rhBMP-2.Study DesignReview of adverse events reported to the FDA after the use of rhBMP-2 (INFUSE Bone Graft) in spinal surgery.MethodsThe Manufacturer and User Facility Device Experience database was searched for the brand name "infuse bone graft," for reports received from July 2, 2002, through August 31, 2011. Adverse events were reviewed, summarized, and classified by an MD. For each report, the most important clinical entity was identified as the principal adverse event. Off-label uses were summarized.ResultsOf 834 reports, four (0.5%) described procedures in which rhBMP-2 was used in accordance with the approved indication. Nearly half of all the reports, 370 (44.4%), stated that the patient required revision surgery or other invasive interventions to address the reported adverse event. Swelling, fluid collections, osteolysis, pain/radiculopathy, heterotopic bone, pseudarthrosis, surgical site infections and other wound complications, thromboembolic events, respiratory distress, cancer, and other events were reported.ConclusionsBecause of their duration, scope, and expense, prospective studies designed to estimate the risk of rare adverse events may be impractical. Despite its imperfections, postmarketing surveillance helps to narrow the focus by revealing patterns and prioritizing topics for further research. One should not extrapolate from these results to the rhBMP-2 experience as a whole; the findings reported here might not be representative. This analysis indicates that serious adverse events can occur after the use of rhBMP-2 in spinal surgery and raises many points that surgeons may wish to consider when deciding when and how to use this product in their patients.Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.