• J Am Soc Echocardiogr · Nov 2014

    Three-dimensional color Doppler transesophageal echocardiography for mitral paravalvular leak quantification and evaluation of percutaneous closure success.

    • Eduardo Franco, Carlos Almería, Jose Alberto de Agustín, Viviana Arreo Del Val, José Juan Gómez de Diego, Miguel Ángel García Fernández, Carlos Macaya, Leopoldo Pérez de Isla, and Eulogio Garcia.
    • Cardiovascular Institute, Hospital Clínico San Carlos, Madrid, Spain. Electronic address: efranco@academiamir.com.
    • J Am Soc Echocardiogr. 2014 Nov 1;27(11):1153-63.

    BackgroundThree-dimensional (3D) color Doppler transesophageal echocardiography (TEE) enables accurate planimetry of the effective regurgitant orifice (ERO) of a mitral paravalvular leak (PVL). The aim of this study was to evaluate the usefulness of this method to quantify paravalvular regurgitation and to assess percutaneous PVL closure success, compared with 3D planimetry of PVLs without using color-flow images (3D anatomic regurgitant orifice [ARO]).MethodsForty-six patients (59 mitral PVLs) who underwent 3D TEE to evaluate the indication of PVL closure procedure were retrospectively included. Receiver operating characteristic curves were compared to identify degree III and IV paravalvular regurgitation of 3D color ERO and 3D ARO measures. Forty patients underwent percutaneous PVL closure procedures; analysis was conducted to determine whether the undersizing of the closure devices according to 3D color ERO and 3D ARO measures was associated with PVL closure failure.ResultsThree-dimensional ERO measures showed better areas under the curve than 3D ARO measures and correlated better with the degree of paravalvular regurgitation. Three-dimensional color ERO major diameter ≥ 0.65 cm showed a positive predictive value of 87.1% and a negative predictive value of 94% to diagnose degree III and IV paravalvular regurgitation. For the 40 patients who underwent PVL closure procedures, the immediate technical success rate was 76.9%, and 1-year estimated survival was 69.5%. Closure device undersizing according to 3D color ERO length, but not other PVL measurements, was significantly associated with PVL closure failure (P = .007).ConclusionThree-dimensional ERO was superior to 3D ARO at identifying the presence of degree III and IV paravalvular regurgitation. The undersizing of closure devices according to 3D color ERO length was associated with failed closure procedures. Confirmatory prospective studies are encouraged.Copyright © 2014 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.