• Chinese Med J Peking · Jan 2014

    Randomized Controlled Trial

    Novel completed biodegradable polymer sirolimus-eluting stent versus durable polymer sirolimus-eluting stent in de novo lesions: nine-month angiographic and three-year clinical outcomes of HOPE trial.

    • Fei Yuan, Xin Chen, Xiantao Song, Dongqi Wang, Zheng Zhang, Weimin Li, Zhanquan Li, Hui Li, Xinyi Chen, Yong Huo, Lefeng Wang, Caiyi Lu, Qinghua Lu, Bo Xu, Wei Li, Shuzheng Lyu, and HOPE Investigator.
    • Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, Beijing 100029, China.
    • Chinese Med J Peking. 2014 Jan 1;127(14):2561-6.

    BackgroundDrug-eluting stents (DES) with durable polymer have significantly reduced restenosis and target vessel revascularization compared with bare metal stents. Durable polymer has been linked with persistent inflammation of vessel wall and delayed endothelial healing that may increase the risk of late and very late stent thrombosis. This study sought to evaluate the efficacy and safety of HELIOS completed biodegradable polymer sirolimus-eluting stent (SES) in de novo coronary lesions.MethodsTotally, 287 patients with one or two de novo coronary lesions (lesion length ≤ 38 mm and reference vessel diameter 2.5-4.0 mm) were enrolled in the HOPE study, a prospective, multicenter, randomized, non-inferiority trial. Patients were randomized to treatment either with HELIOS completed biodegradable polymer SES (n = 142) or PARTNER durable polymer SES (n = 145). The primary endpoint was angiographic in-stent late lumen loss (LLL) at 9-month follow-up. The secondary endpoint included stent thrombosis and major adverse cardiac events including cardiac death, myocardial infarction (MI) and target lesion revascularization (TLR).ResultsThe 9-month in-stent LLL in the HELIOS group was similar to the PARTNER group, (0.16 ± 0.22) mm vs. (0.19 ± 0.30) mm (P = 0.28). The difference and 95% confidence interval were -0.03 (-0.09, 0.04), and the P value for non-inferiority <0.01. Major adverse cardiovascular event (MACE) occurred in 7.9% vs. 8.2%, MI in 2.4% vs. 3.0%, TLR in 5.5% vs. 3.0%, and stent thrombosis in 0 vs. 1.5%; and events were comparable between the HELIOS group and PARTNER group at three-year follow-up (all P > 0.05). The three-year cardiac death was lower in the HELIOS group, but with no significant difference, 0 vs. 3.0% (P = 0.12).ConclusionsIn the HOPE trial, the novel completed biodegradable polymer SES HELIOS was non-inferior to the durable polymer SES PARTNER with respect to nine-month in-stent LLL in de novo coronary lesions. The incidence of other clinical endpoints was low for both of the stents in three-year follow-up.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.