• J Pediatr Orthop · Mar 2008

    Comparative Study

    Displaced olecranon fractures in children: a biomechanical analysis of fixation methods.

    • Stefan Parent, Michelle Wedemeyer, Andrew T Mahar, Megan Anderson, Frances Faro, Suzanne Steinman, François Lalonde, and Peter Newton.
    • Hospital St Justine, Montreal, Quebec, Canada.
    • J Pediatr Orthop. 2008 Mar 1;28(2):147-51.

    BackgroundWire and suture methods have been used to stabilize pediatric olecranon fractures. This study (1) compared differences in simulated intraoperative compression during fracture reduction, (2) evaluated articular surface compression during cyclic loading of the tension band, and (3) compared fracture stabilization after cyclic physiologic loading at low/high levels.MethodsIdentical olecranon fractures were created in 10 synthetic ulnae and randomized to suture or wire fixation. Compression after fixation and compression during cyclic loading between 10 and 50 N was measured with a load cell at the articular surface and compared with a 1-way analysis of variance (p < 0.05). Twenty-four fractured synthetic ulna were randomly assigned to wire or suture tension band constructs and low- or high-loading groups. The low-load group (12 ulnae) cycled loading from 3 to 10 N for 100 cycles followed by a failure test. The high-load group (12 ulnae) experienced 10 to 100 N before failure testing. Fracture separation (mm) and failure load (N) were compared using a 2-way analysis of variance (p < 0.05). Ten synthetic ulnae were randomized to wire/suture groups and cyclically loaded between 10 to 50 N while measuring loads across the fracture using a load cell. Correlation data were statistically compared with a Fisher transformation and z test (p < 0.05).ResultsResidual compression was statistically greater for wire compared with suture. There was no difference in fracture displacement between groups during low loads. Suture had significantly greater displacement compared with wire at high loads. Failure loads were significantly greater for wire at both load settings. Wires transmitted forces across the joint surface more readily than sutures.ConclusionsSuture tension bands had lower ultimate failure loads and less compression at the fracture site. However, if low loads are expected or if the fracture is reduced easily, the suture tension band may be an appropriate alternative to wire fixation.Clinical RelevancePerhaps, in small children or when using casts in bigger children, a bioabsorbable suture may be used for fracture stabilization avoiding the need for extensive surgery to remove the fixation material.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,624,503 articles already indexed!

We guarantee your privacy. Your email address will not be shared.