• J Orthop Trauma · Jan 2016

    Comparative Study

    Rotationally Stable Screw-Anchor With Locked Trochanteric Stabilizing Plate Versus Proximal Femoral Nail Antirotation in the Treatment of AO/OTA 31A2.2 Fracture: A Biomechanical Evaluation.

    • Matthias Knobe, Philipp Nagel, Klaus-Jürgen Maier, Gertraud Gradl, Benjamin Buecking, Tolga T Sönmez, Ali Modabber, Andreas Prescher, and Hans-Christoph Pape.
    • *Department of Orthopaedic Trauma, University of Aachen Medical Center, Germany;†Department of Surgery, RoMed Hospital Bad Aibling, Germany;‡Department of Trauma, University Hospital Gießen and Marburg GmbH, Campus Marburg, Germany; andDepartments of §Oral and Maxillofacial Surgery, and‖Molecular and Cellular Anatomy, University of Aachen Medical Center, Aachen, Germany.
    • J Orthop Trauma. 2016 Jan 1; 30 (1): e12-8.

    ObjectivesThird-generation cephalomedullary nails currently represent the gold standard in the treatment of unstable trochanteric femur fractures. Recently, an extramedullary rotationally stable screw-anchor system (RoSA) has been developed. It was designed to combine the benefits of screw and blade and to improve stability using a locked trochanteric stabilizing plate (TSP). The purpose of this study was to compare the biomechanical behavior of RoSA/TSP and the proximal femoral nail antirotation (PFNA).MethodsStandardized AO/OTA 31A2.2 fractures were induced by an oscillating saw in 10 paired human specimens (n = 20; mean age = 85 years; range: 71-96 years). The fractures were stabilized by either the RoSA/TSP (Koenigsee Implants, Allendorf, Germany) or the PFNA (DePuy Synthes, Zuchwil, Switzerland). Femurs were positioned in 25 degrees of adduction and 10 degrees of posterior flexion and were cyclically loaded with axial sinusoidal pattern at 0.5 Hz, starting at 300 N, with stepwise increase by 300 N every 500 cycles until bone-implant failure occurred. After every load step, the samples were measured visually and radiographically. Femoral head migration was assessed.ResultsThe stiffness at the load up to the clinically relevant load step of 1800 N (639 ± 378 N/mm (RoSA/TSP) vs. 673 ± 227 N/mm (PFNA); P = 0.542) was comparable, as was the failure load (3000 ± 787 N vs. 3780 ± 874 N; P = 0.059). Up to 1800 N, no femoral head rotation, head migration, or femoral neck shortening were observed either for RoSA/TSP or PFNA. Whereas failure of the PFNA subsumed fractures of the greater trochanter and the lateral wall, a posterior femoral neck fracture with a significantly increased femoral neck shortening (1.7 mm vs. 0 mm; P = 0.012) was the cause of failure with RoSA/TSP. This specific kind of failure was induced by a femoral neck weakening caused by the posterior TSP stabilizing screw.ConclusionsThere was no significant difference in biomechanical properties between the RoSA/TSP and the PFNA for the fracture pattern tested. However, failure modes differed between the 2 implants with greater femoral neck shortening observed in the RoSA/TSP group.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.