-
Rev Esp Anestesiol Reanim · Aug 2012
Observational Study[The finding of glucose in the fluid obtained by epidural catheter after its insertion during combined intradural-epidural anaesthesia with hyperbaric bupivacaine is a usual occurrence].
- J Sánchez Morillo, M J Estruch Pérez, J Balaguer Doménech, L Gallen Martín, M J Hernández Cádiz, and C Solaz Roldán.
- Servicio de Anestesiología y Reanimación, Hospital Universitario Dr. Peset, Valencia, España.
- Rev Esp Anestesiol Reanim. 2012 Aug 1;59(7):357-62.
ObjectivesTo determine whether the appearance of glucose in the fluid spontaneously obtained by the epidural catheter after its insertion during combined intradural-epidural anaesthesia with hyperbaric bupivacaine is a usual occurrence.Patients And MethodsA prospective, observational study was conducted on 34 patients with combined intradural-epidural anaesthesia in whom an epidural catheter was introduced, after locating the epidural space with a saline solution, inserting a spinal needle and injecting hyperbaric bupivacaine. After observing whether any fluid was spontaneously dripping from it, it was determined if this contained glucose. Withdrawal of the needle and washing its lumen with saline solution, it was checked whether there was glucose in washout. The samples were analysed using a glucose meter. When the motor block disappeared a dose of local anaesthetic was administered through the epidural catheter. The relationship of the demographic parameters with the spontaneous dripping of the epidural catheter was evaluated.ResultsSpontaneous dripping by the epidural catheter after its insertion was observed in 22 patients. All the samples obtained contained glucose. There was glucose in 9 out of 34 epidural needle wash samples. None of the patients suffered from excessive motor-sensory block. There was a statistically significant relationship between patient age (P<.05) and spontaneous dripping by the catheter (the higher the age, more dripping).ConclusionThe finding of glucose in the fluid obtained by the epidural catheter is a frequent occurrence and is of no clinical significance. We propose that it could be due to a leak of cerebrospinal fluid by the dural puncture needle during or after the administering of the hyperbaric bupivacaine and the spillage of this into the epidural space.Copyright © 2010 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.