- Shuang Li, Shi-Min Chang, Yan-Min Jin, Ying-Qi Zhang, Wen-Xin Niu, Shou-Chao Du, Li-Zhi Zhang, and Hui Ma.
- Department of Orthopaedic Surgery, Yangpu Hospital, Tongji University School of Medicine, Shanghai, China.
- Injury. 2016 Jun 1; 47 (6): 1302-8.
BackgroundAs a predictor of the risk of lag screw cutout, it was recommended that keeping tip-apex distance (TAD)<25mm and placing the screw centrally or inferiorly, but positioning the lag screw too inferiorly in the head would produce TAD>25mm. We aim to simulate various positions of the lag screw in the femoral head and identify whether 25mm is a suitable cut-off value that favours all sizes of femoral heads with intertrochanteric fractures of the hip.MethodsUsing a general mathematical software, the positions of the screw tip points were simulated. The virtual anterior-posterior and lateral views were then visualised, and the locus of the screw tips was projected into a Cartesian coordinate system according to the TAD and calcar-referenced tip-apex distance (CalTAD) formulas. Each original virtual anterior-posterior and lateral image was zoomed and compiled to match a calculated average image. The screw tip points were recorded, traced and compiled into volumes which could be used to visualise the screw's movements and positioning within the femoral head. The extracted volumes were calculated when 10mm
ResultsFor the TAD calculation, the shape of the traced screw tip points had a pancake-like appearance, while the CalTAD plot produced a teardrop-shaped region. The volume ratios of TAD, CalTAD and overlapping region relative to the femoral head volume were respectively 3.51±1.30%, 5.19±1.62% and 2.64±1.32%. The volumes of the traced TAD, CalTAD and overlapping regions increased slower than the volume of an idealised sphere.ConclusionPositioning the lag screw should address geometrical effects of both tip-apex distance and femoral head size, with an emphasis on measuring the position of the screw tip for the suitable zone by volume ratio. The previous 25mm TAD cut-off value should be adjusted according to the individual femoral head size.Copyright © 2016 Elsevier Ltd. All rights reserved. Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.