-
Critical care medicine · Apr 1994
Comparative StudyContinuous intra-arterial blood gas and pH monitoring in critically ill patients with severe respiratory failure: a prospective, criterion standard study.
- M Haller, E Kilger, J Briegel, H Forst, and K Peter.
- Department of Anesthesiology, Ludwig-Maximilians-University of Munich, FRG.
- Crit. Care Med. 1994 Apr 1; 22 (4): 580-7.
ObjectiveTo evaluate the routine clinical performance of a new intra-arterial fiberoptic blood gas sensor that provides continuous PO2, PCO2, and pH monitoring.DesignCriterion standard study under routine clinical conditions.SettingIntensive care unit (ICU) in a university hospital.PatientsTwenty-two sensors were tested in 13 patients with acute respiratory failure, including two patients receiving veno-venous extracorporeal lung assist. Patient selection was based on the necessity of frequent blood gas monitoring.MeasurementsSensor-deprived PO2, PCO2, and pH values were compared with values obtained using two different conventional laboratory blood gas analyzers located in the ICU. The median study period was 72 hrs per sensor (range 8 to 170 hrs). The quality of blood pressure readings with the sensor introduced through the arterial catheter was assessed by a grading system.ResultsMean differences between sensor-derived values and the average values of the two conventional blood gas analyzers were as follows: PO2 -2.4 +/- 6.5 (SD) torr (-0.3 +/- 0.9 kPa), PCO2 -2.9 +/- 3.9 torr (-0.4 +/- 0.5 kPa), and pH -0.04 +/- 0.03. Correlation coefficients were 0.99 (PO2), 0.94 (PCO2), and 0.89 (pH), respectively. The agreement between the two methods for PO2 measurement was better for the clinically important range of values (PO2 < 150 torr [< 20 kPa]) than for all measured PO2 values (range 30 to 522 torr [4 to 69.6 kPa]). Blood withdrawal and pressure readings were not adversely affected by the sensor. No side effects due to the insertion of the sensor were observed.ConclusionsThe degree of agreement of intra-arterial blood gas sensor values with conventional blood gas analysis is within an acceptable range for routine clinical purposes. Acute changes in measured values are detected reliably. Continuous intra-arterial blood gas analysis can add substantially to the safety of patients with acute respiratory failure and can reduce blood sampling requirements for blood gas analysis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.