Observational Study
Intraoperative positive end-expiratory pressure evaluation using the intratidal compliance-volume profile.
- S Wirth, M Baur, J Spaeth, J Guttmann, and S Schumann.
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Freiburg, Hugstetter Straße 55, Freiburg D-79106, Germany steffen.wirth@uniklinik-freiburg.de.
- Br J Anaesth. 2015 Mar 1; 114 (3): 483-90.
BackgroundLung-protective mechanical ventilation during general surgery including the application of PEEP can reduce postoperative pulmonary complications. In a prospective clinical observation study, we evaluated volume-dependent respiratory system compliance in adult patients undergoing ear-nose-throat surgery with ventilation settings chosen empirically by the attending anaesthetist.MethodsIn 40 patients, we measured the respiratory variables during intraoperative mechanical ventilation. All measurements were subdivided into 5 min intervals. Dynamic compliance (CRS) and the intratidal volume-dependent CRS curve was calculated for each interval and classified into one of the six specific compliance profiles indicating intratidal recruitment/derecruitment, overdistension or all. We retrospectively compared the occurrences of the respective compliance profiles at PEEP levels of 5 cm H2O and at higher levels.ResultsThe attending anaesthetists set the PEEP level initially to 5 cm H2O in 29 patients (83%), to 7 cm H2O in 5 patients (14%), and to 8 cm H2O in 2 patients (6%). Across all measurements the mean CRS was 61 (11) ml cm H2O(-1) (40-86 ml cm H2O(-1)) and decreased continuously during the procedure. At PEEP of 5 cm H2O the compliance profile indicating strong intratidal recruitment/derecruitment occurred more often (18.6%) compared with higher PEEP levels (5.5%, P<0.01). Overdistension was practically never observed.ConclusionsIn most patients, a PEEP of 5 cm H2O during intraoperative mechanical ventilation is too low to prevent intratidal recruitment/derecruitment. The analysis of the intratidal compliance profile provides the rationale to individually titrate a PEEP level that stabilizes the alveolar recruitment status of the lung during intraoperative mechanical ventilation.Trial Registration NumberDRKS00004286.© The Author 2014. Published by Oxford University Press on behalf of the British Journal of Anaesthesia. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]