• J. Surg. Res. · Sep 1986

    The thermal-dye method of lung water measurement is reliable at a low cardiac output.

    • D E Calcagni, F G Mihm, T W Feeley, B D Halperin, and M H Rosenthal.
    • J. Surg. Res. 1986 Sep 1; 41 (3): 286-92.

    AbstractThe measurement of lung water by the thermal-dye double indicator dilution technique was evaluated in dogs with normal and edematous lungs during a state of reduced cardiac output. The technique used cold indocyanine green dye to measure extravascular thermal volume (EVTV) as an estimate of extravascular lung water (EVLW). Anesthesia was maintained with pentobarbital. In 15 of 21 animals, pulmonary edema was first induced with oleic acid (0.75 to 0.18 ml/kg). Cardiac output (CO) was then decreased by a combination of propranolol and slow exsanguination (mean CO reduction to 36% of baseline). Extravascular lung water produced in this model ranged from 1.4 to 30.2 ml/kg. Predetermination measurements of EVTV correlated closely with EVLW as determined by gravimetric analysis (EVTV = 1.1 EVLW + 4.7 ml/kg, n = 21, r = 0.93, P less than 0.001). Thermodilution cardiac output measured in the abdominal aorta (used in the calculation of the EVTV) correlated well with simultaneous measurements of cardiac output by both indocyanine green dye dilution and pulmonary artery thermodilution (r = 0.86 and r = 0.88, respectively, pretermination). The thermal-dye technique appears to provide an accurate reflection of lung water in normal and edematous lungs, even in the presence of a low cardiac output.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…