-
Minerva anestesiologica · Dec 2016
Randomized Controlled Trial Comparative StudyComparison of the Macintosh, GlideScope®, Airtraq®, and King VisionTM laryngoscopes in routine airway management.
- Abdulmohsen A Al-Ghamdi, Mohamed R El Tahan, and Alaa M Khidr.
- Department of Anesthesiology, King Fahd Hospital, University of Dammam, Al Khobar, Saudi Arabia.
- Minerva Anestesiol. 2016 Dec 1; 82 (12): 1278-1287.
BackgroundWe hypothesized that the use of the channeled King Vision™ and Airtraq® would shorten the time for tracheal intubation compared with the Macintosh or GlideScope® laryngoscopes in patients with normal airways.MethodsEighty-six patients were randomly assigned to intubate the trachea using either the Macintosh (N.=22), Glidescope® (N.=21), Airtraq® (N.=21), or King Vision™ (N.=22) laryngoscope. The primary outcome was the time to tracheal intubation. Secondary outcomes included the laryngoscopic view, numbers of laryngoscopy attempts, first-pass success rate, optimization maneuvers, ease of intubation, and postoperative sore throat.ResultsCompared with the Macintosh and GlideScope®, the use of the channeled videolaryngoscopes had significantly longer times to tracheal intubation (mean times: Airtraq® 44 s [95% CI: 39.6 to 46.7]; King Vision™ 34.5 s [95% CI: 33.1 to 40.2]; Macintosh 20 s [95% CI: 19.7 to 26.7]; GlideScope® 27.9 s [95% CI: 25.1 to 30.7], P<0.002) and caused less mucosal trauma (P=0.006). The King Vision™ is slightly faster than the Airtraq® (P=0.035). Compared with the Macintosh and the Airtraq®, the GlideScope® was easier to use (P<0.001). The 4 groups had comparable glottis views, number of laryngoscopy and optimising manoeuvres and first attempt success rate. The Airtraq® and King Vision™ had a lower incidence of sore throat than with the Macintosh or GlideScope® (P=0.001). No patient had failed intubation.ConclusionsThe King Vision™ and Airtraq® require longer intubation times, as primary outcome, and cause less sore throat than the Macintosh and GlideScope® when used by anesthesiologists with limited experience in patients with normal airways. Our conclusion is difficult to extrapolate to the expert anesthesiologists who are using videolaryngoscopes on a regular basis.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.