    Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support.

    • Stefan Klotz, Mario C Deng, Joerg Stypmann, Juergen Roetker, Markus J Wilhelm, Dieter Hammel, Hans H Scheld, and Christof Schmid.
    • Department of Thoracic and Cardiovascular Surgery, University Hospital, Muenster, Germany. stefan.klotz@thmgs.uni-muenster.de
    • Ann. Thorac. Surg. 2004 Jan 1; 77 (1): 143-9; discussion 149-50.

    BackgroundNonpulsatile axial or centrifugal pumps are the latest generation of left ventricular assist devices (LVAD). Whether left ventricular (LV) unloading and outcome in these devices is similar to pulsatile LVADs during long-term support has not been investigated. We compared LV unloading and mortality between different types of LVAD support (pulsatile versus nonpulsatile).MethodsIn 31 patients undergoing long-term LVAD implantation (nonpulsatile = 10, pulsatile = 21) preoperative and postoperative echocardiographic and hemodynamic assessment with right heart catheterization had been obtained.ResultsAll patients had similar echocardiographic, hemodynamic, and clinical heart failure characteristics at baseline. The degree of LV pressure unloading was the same in both device types, caused by similar reduction of mean pulmonary pressure (18.6 +/- 5.1 versus 18.3 +/- 7.5 mm Hg) and pulmonary capillary wedge pressure (8.9 +/- 4.4 versus 8.0 +/- 7.0 mm Hg). Left ventricular volume unloading was pronounced with a pulsatile device owing to a statistically significant higher pump output (5.1 +/- 1.0 L/min) in comparison with nonpulsatile LVADs (3.6 +/- 0.9 L/min, p < 0.001). Echocardiographic-determined end-systolic indicators confirm this augmentation in pulsatile LVADs. Etiology or the time interval of hemodynamic reassessment had no impact in left ventricular pressure unloading, but LV volume unloading decreased between day 60 and 120 in patients with nonpulsatile LVADs. The preoperative and postoperative transplant mortality was comparable in both groups.ConclusionsLeft ventricular pressure unloading is similar in patients with nonpulsatile as compared with pulsatile implantable long-term assist devices. Left ventricular volume unloading is pronounced in pulsatile LVADs.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.