-
- Sameh Sayfo, Kairav P Vakil, Ahmad Alqaqa'a, Helen Flippin, Deepak Bhakta, Anil V Yadav, John M Miller, and William J Groh.
- Department of Medicine, Division of Cardiology, Krannert Institute of Cardiology, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.
- Heart Rhythm. 2012 Mar 1; 9 (3): 342-6.
BackgroundThere is controversy whether proceduralist-directed, nurse-administered propofol sedation (PDNAPS) is safe.ObjectiveTo assess the frequency of adverse events when PDNAPS is used for implantable cardioverter-defibrillator (ICD)-related procedures and to determine the patient and procedural characteristics associated with adverse events.MethodsConsecutive ICD-related procedures using PDNAPS from May 2006 to July 2009 at a tertiary-care hospital were evaluated. Serious adverse events were defined as procedural death, unexpected transfer to an intensive care unit, respiratory failure requiring intubation/bag-mask ventilation, or hypotension requiring vasoconstrictor/inotrope support. Nonserious adverse events were defined as hypotension requiring fluid resuscitation or hypoxemia requiring augmented respiratory support with non-rebreather mask, oral airway, or jaw lift.ResultsOf 582 patients (age 64 ± 14 years, 72.3% males) undergoing ICD-related procedures using PDNAPS, 58 (10.0%) patients had serious adverse events with no procedural death and 225 (38.7%) had nonserious adverse events. Longer procedure duration (relative risk [RR] = 2.1 per hour; 95% confidence interval [CI] = 1.6-2.8; P < .001) and biventricular implant (RR = 2.7; CI = 1.4-5.3; P = .003) were independent predictors of serious adverse events. A longer procedure duration (RR = 1.4 per hour; CI = 1.1-1.7; P = .001), heart failure class (RR = 1.4 per 1 class; CI = 1.1-1.7; P = .002), and use of propofol infusion (RR = 3.5; CI = 2.2-5.7; P < .001) were independent predictors of nonserious adverse events.ConclusionPDNAPS for shorter ICD procedures including single- and dual-chamber implants, generator changes, and defibrillation threshold testing have acceptable rates of serious adverse events and manageable nonserious adverse events and should be considered for further study. Biventricular implants and other complex procedures should be done with an anesthesiologist.Copyright © 2012 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.