• Clin. Orthop. Relat. Res. · Jul 2007

    Computer navigation allows for accurate reduction of femoral fractures.

    • Yoram A Weil, Michael J Gardner, David L Helfet, and Andrew D Pearle.
    • Orthopaedic Trauma Service, Hospital for Special Surgery, New York, NY, USA. yoramweil@gmail.com
    • Clin. Orthop. Relat. Res. 2007 Jul 1; 460: 185-91.

    AbstractFemoral nailing for reduction and stabilization of femoral fractures is a common orthopaedic procedure. However, angular and rotational malalignment is not an infrequent result, and extensive use of fluoroscopy is commonly involved. We tested the accuracy of a computerized navigation system to enhance multiplanar fracture reduction and to decrease the requirement for fluoroscopy. We used a cadaveric femur fixed in a simulator and optically tracked. After obtaining five fluoroscopic images for each reduction attempt, accuracy measurements were taken. We first measured alignment of the intact bone using the navigation system, followed by open and blind reduction of simple and segmental fractures. For the blind, closed reduction trials, the accuracy of restoration of femoral length was 1.2 +/- 0.4 mm (mean +/- standard deviation) for a simple fracture and 1.9 +/- 1.8 mm for a segmental fracture. Rotational accuracy was 1.7 degrees +/- 1.9 degrees and 2.5 degrees +/- 1.8 degrees, respectively. Open reduction using this model yielded no difference between the reduced fracture and the intact bone in coronal and rotational alignment. Computerized navigation has the potential for increasing precision in fracture reduction while minimizing fluoroscopic requirements.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…