• Zhonghua Wai Ke Za Zhi · May 2009

    [The assessment of accuracy and safety of thoracic pedicle screws placement with interlaminar fenestration technique in severe kyphoscoliosis treatment].

    • Bing Wang, Guo-hua Lü, Yi-jun Kang, Jing Li, Fei Chen, You-wen Deng, and Wei-dong Liu.
    • Department of Spine Surgery, Second Xiangya Hospital, Central South University, Changsha 410011, China. bingwang20021972@yahoo.com.cn
    • Zhonghua Wai Ke Za Zhi. 2009 May 15; 47 (10): 770-3.

    ObjectiveTo analyze the accuracy and safety of thoracic pedicle screws placement with interlaminar fenestration technique in severe kyphoscoliosis treatment.MethodsTwenty-three cases of severe kyphoscoliosis between June 1996 and December 2007 underwent pedicle screw placement of thoracic vertebrae by interlaminar fenestration technique. Postoperative CT scan was performed in all cases; there were 9 males and 14 females with the averaging age 17.8 years old. The preoperative Cobb angle of the main thoracic curve was 97.3 degrees in average. The average kyphotic angle in main curve was 67.4 degrees . Patients who underwent screw placement by closing technique and postoperative CT scan in the same stage with severe kyphoscoliosis were selected as control group (B): there were 22 patients with the averaging age 17.2 years old. The preoperative Cobb angle of the main thoracic curve was 96.6 degrees in average. The average kyphotic angle in main curve was 62.1 degrees . The screw-related complications were analyzed and online measure and analyze the degree of screw penetration according to CT by statistics.ResultsThere were 209 thoracic pedicle screws being inserted in group A, no spinal cord and large blood vessel injury occurred, 5 patients occurred intraoperative pedicle fracture, dura lesion had 4 patients. Screws misplacement ratio was 8.6%, there were 11 screws located in the thoracic pedicle laterally, 6 screws located in medially, 1 screw presented a moderate anterior cortical perforation. The number of screws misplacement in upper and mild thoracic vertebrae were 15, occupied 83.3%; the number of screws misplacement in lower thoracic vertebrae were 3, occupied 16.7%. There was statistics difference (P < 0.05). Of the total 116 thoracic pedicle screws inserted on the convex side, the ratio of screw misplacement was 5.2%; 93 screws on the concave side, the ratio of screw misplacement was 12.9%, there was statistics difference (P < 0.05). There were 201 thoracic pedicle screws being inserted in group B, no spinal cord and large blood vessel injury occurred, 16 patients occurred intraoperative pedicle fracture, dura lesion had 7 patients. The ratio of screw misplacement was 22.4%, there were 24 screws located in the thoracic pedicle laterally, 11 screws located in medially, 10 screw presented a moderate anterior cortical perforation. The ratio of screw misplacement in Group B was higher than Group A (P < 0.05). All cases received 3.2 years and 3.4 years follow-up. There was no obvious loss of correction in coronal and sagittal plane at the latest follow-up.ConclusionsIt is technically demanding for placement of thoracic screw in the severe kyphoscoliosis treatment. The interlaminar fenestration technique can increase the accuracy and safety of thoracic pedicle screw placement.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.