J. Cardiothorac. Vasc. Anesth. · Jan 2015
Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes.
- Koichi Suehiro, Katsuaki Tanaka, Mika Mikawa, Yuriko Uchihara, Taiki Matsuyama, Tadashi Matsuura, Tomoharu Funao, Tokuhiro Yamada, Takashi Mori, and Kiyonobu Nishikawa.
- Department of Anesthesiology, Osaka City University Graduate School of Medicine, Osaka City, Osaka, Japan. Electronic address: suehirokoichi@yahoo.co.jp.
- J. Cardiothorac. Vasc. Anesth. 2015 Jan 1; 29 (3): 656-62.
ObjectivesThe aims of this study were to compare cardiac output (CO) measured by the new fourth-generation FloTrac™/Vigileo™ system (Version 4.00) (COFVS) with that measured by a pulmonary artery catheter (COREF), and to investigate the ability of COFVS to track CO changes induced by increased peripheral resistance.DesignProspective study.SettingUniversity Hospital.ParticipantsTwenty-three patients undergoing cardiac surgery.InterventionsPhenylephrine (100 µg) was administered.Measurements And Main ResultsHemodynamic variables, including CO(REF) and CO(FVS), were measured before and after phenylephrine administration. Bland-Altman analysis was used to assess the discrepancy between CO(REF) and CO(FVS). Four-quadrant plot and polar-plot analyses were utilized to evaluate the trending ability of CO(FVS) against CO(REF) after phenylephrine boluses. One hundred thirty-six hemodynamic interventions were performed. The bias shown by the Bland-Altman analysis was-0.66 L/min, and the percentage error was 55.4%. The bias was significantly correlated with the systemic vascular resistance index (SVRI) before phenylephrine administration (p<0.001, r(2) = 0.420). The concordance rate determined by four-quadrant plot analysis and the angular concordance rate calculated using polar-plot analysis were 87.0% and 83.0%, respectively. Additionally, this trending ability was not affected by SVRI state.ConclusionsThe trending ability of the new fourth-generation FloTrac™/Vigileo™ system after increased vasomotor tone was greatly improved compared with previous versions; however, the discrepancy of the new system in CO measurement was not clinically acceptable, as in previous versions. For clinical application in critically ill patients, this vasomotor tone-dependent disagreement must be decreased.Copyright © 2015 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.