• Prehosp Disaster Med · Sep 2009

    Randomized Controlled Trial

    Evaluation of bag-valve-mask ventilation by paramedics in simulated chemical, biological, radiological, or nuclear environments.

    • Jan Schumacher, Lena Weidelt, Stuart A Gray, and Andrea Brinker.
    • Consultant Anesthetist and Honorary Senior Lecturer, King's College, St. Thomas' Campus, London, UK. Jan.Schumacher@kcl.ac.uk
    • Prehosp Disaster Med. 2009 Sep 1; 24 (5): 398-401.

    IntroductionBag-valve-mask ventilation is a key component of life support, but only one handheld resuscitator is designed to operate in contaminated or toxic atmospheres.MethodsAfter Institutional Review Board approval, the efficacy of this device was evaluated. The distal trachea of a Laerdal Airway Management Trainer was connected to a mechanical Draeger Volumeter 3000, to enable determination of the minute volume delivered by BVM ventilation. Nineteen paramedics wearing chemical, biological, radiological, or nuclear (CBRN) protective equipment were asked to ventilate this modified airway trainer, either with or without a CBRN filter attached to the inlet filtration system of the AMBU Mark III Resuscitator. The maximum levels of minute ventilation achieved were compared. Values are given as mean +/-SD. A paired t-test was used to detect any differences between the two groups, p-values of <0.05 were defined to show statistical significance.ResultsThe described model allowed a reproducible and reliable measurement of the delivered minute ventilation. All paramedics were able to operate the device without prior CBRN training. The maximum minute volume achieved without the filter was 9.5 +/-2.7 l/min. Use of the inlet CBRN filtration system reduced the maximum minute volume to 6.3 +/-2.0 l/min, reduction: 23%. The achieved maximum minute volumes ranged from 15 to 4.9 l/min in the controls and from 9.8 to 1.4 l/min in the CBRN group. Four paramedics were unable to achieve a minute volume >5 l/min in the CBRN group, one participant failed to achieve that value in the control group. The inherent breathing resistance of the CBRN filter appears to reduce the inflow of air into the self-inflatable bag. This delay in refilling may have resulted in a reduced achievable minute volume.ConclusionsThe range of maximum minute volumes observed in both groups highlights the need for continuous BVM ventilator training.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.