Clinical Trial
Feasibility, accuracy, and incremental value of intraoperative three-dimensional transesophageal echocardiography in valve surgery.
- T P Abraham, J G Warner, N D Kon, P E Lantz, K M Fowle, R F Brooker, S Ge, A M Nomeir, and D W Kitzman.
- Department of Cardiothoracic Surgery, Bowman Gray School of Medicine of Wake Forest University, Winston-Salem, North Carolina 27157-1045, USA.
- Am. J. Cardiol. 1997 Dec 15; 80 (12): 1577-82.
AbstractIn this prospective trial, intraoperative 2-dimensional (2-D) and 3-dimensional (3-D) transesophageal echocardiography (TEE) examinations were performed on 60 consecutive patients undergoing cardiac valve surgery. Both 2-D (including color flow and Doppler data) and 3-D images were reviewed by blinded observers, and major valvular morphologic findings recorded. In vivo morphologic findings were noted by the surgeon and all explanted valves underwent detailed pathologic examination. To test reproducibility, 6 patients also underwent 3-D TEE 1 day before surgery. A total of 132 of 145 attempted acquisitions (91%) were completed with a mean acquisition time of 2.8 +/- 0.2 minutes. Acquisition time was significantly shorter in patients with regular rhythms. Reconstructions were completed in 121 of 132 scans (92%) and there was at least 1 good reconstruction in 56 of 60 patients (93%). Mean reconstruction time was 8.6 +/- 0.7 minutes. Mean effective 3-D time, which was the time taken to complete an acquisition and a clinically interpretable reconstruction, was 12.2 +/- 0.8 minutes. Intraoperative 3-D echocardiography was clinically feasible in 52 patients (87%). Three-D echocardiography detected most of the major valvular morphologic abnormalities, particularly leaflet perforations, fenestrations, and masses, confirmed on pathologic examination. Three-D echocardiography predicted all salient pathologic findings in 47 patients (84%) with good quality images. In addition, in 15 patients (25%), 3-D echocardiography provided new additional information not provided by 2-D echocardiography, and in 1 case, 3-D echocardiographic findings resulted in a surgeon's decision to perform valve repair rather than replacement. In several instances, 3-D echocardiography provided complementary morphologic information that explained the mechanism of abnormalities seen on 2-D and color flow imaging. In the reproducibility subset, preoperative and intraoperative 3-D imaging detected a similar number of findings when compared with pathology. Thus, in routine clinical intraoperative settings, 3-dimensional TEE is feasible, accurately predicts valve morphology, and provides additional and complementary valvular morphologic information compared with conventional 2-D TEE, and is probably reproducible.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.