• Acta Anaesthesiol Scand · Jan 1985

    Development and evaluation of a flow-dividing unit for differential ventilation and selective PEEP.

    • M Darowski, G Hedenstierna, and S Baehrendtz.
    • Acta Anaesthesiol Scand. 1985 Jan 1; 29 (1): 61-6.

    AbstractDifferential ventilation with selective positive end-expiratory pressure (PEEP) was studied in a two-compartment lung model, using one ventilator and a flow-dividing unit consisting of inspiratory flow resistors and an inspiratory threshold valve. The compliance of each lung compartment was varied between 0.15 and 0.23 1 X kPa-1 and the resistance was varied from 0 to 3.5 kPa X 1(-1) X s. The minute volume was 12 1 and the respiratory frequency 12/min, with an inspiratory:expiratory ratio of 1:2. An even distribution of ventilation to the two lung compartments was obtained with the inspiratory flow resistors or the threshold valve under all conditions studied. However, a stepwise increase in the inspiratory resistance of one lung compartment from 1.0 to 2.5 or from 2.5 to 3.5 kPa X 1(-1) X s required readjustment of the inspiratory flow resistor to achieve an even distribution of ventilation, whereas the inspiratory threshold valve needed no readjustment. Large differences in the inspiratory impedance of the two lung compartments caused asynchronous gas delivery when the ventilation distribution was adjusted by means of the flow resistors. Use of the threshold valve resulted in synchronous gas delivery. The flow-dividing unit consists of non-active elements and can thus be connected to any ventilator.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.