• J Clin Monit · Sep 1995

    Comparative Study

    Simultaneous in vivo comparison of two-versus three-wavelength mixed venous (Svo2) oximetry catheters.

    • F Bongard, T S Lee, T Leighton, and S Y Liu.
    • Department of Surgery, Harbor-UCLA Medical Center, Torrance, USA.
    • J Clin Monit. 1995 Sep 1; 11 (5): 329-34.

    ObjectiveVenous oximetry catheters provide useful realtime information about mixed venous hemoglobin saturation (Svo2). Currently available systems utilize either two or three wavelengths of light to obtain these measurements. Previous animal and clinical studies have attempted to compare the accuracy of these two devices under similar circumstances. However, the relative accuracy of the two-wavelength versus three-wavelength systems has never been assessed under identical conditions. For this purpose, we designed an animal model for simultaneous measurement of Svo2, over a wide range of physiologic and pathologic states.MethodsSeven anesthetized swine underwent simultaneous placement of two- and three-wavelength catheters. Paired data points consisted of values obtained from a reference oximeter and from each of the catheters. Observations were obtained every 15 min during the following manipulations: (1) eucarbic hypoxia induced by reducing FiO2 to 0.18, 0.15, and 0.12 for 15 min each; (2) stimulated surgical manipulation; and (3) hypovolemic shock produced by hemorrhage to a mean arterial pressure of 50 torr for 1 hr. Data were analyzed by calculation of mean error (bias) and precision for each system in comparison with the oximeter.ResultsThe overall error of the two-wavelength system was +0.15%, with a precision of +/- 2.52%. The three-wavelength system had an overall error of +3.71%, with a precision of +/- 2.30%. Overall correlation between catheter Svo2 and oximeter values was the same for both devices (r = 0.99).ConclusionsBoth currently available in vivo spectrophotometric systems are capable of producing satisfactory results over wide ranges of Svo2. In contradistinction to older reports, we found that the two-wavelength Svo2 system produced results equivalent to those obtained from the three-wavelength device. In this regard, there is no detectable advantage in accuracy to measuring in vivo Svo2 with three rather than with two wavelengths.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.