• Critical care medicine · Sep 1992

    Continuous breathing circuit flow and tracheal tube cuff leak: sources of error during pediatric indirect calorimetry.

    • J Räsänen.
    • Department of Anesthesiology, University of South Florida, College of Medicine, Tampa 33612.
    • Crit. Care Med. 1992 Sep 1; 20 (9): 1335-40.

    ObjectiveTo determine whether continuous gas flow in the breathing circuit or an airleak around the tracheal tube cuff will introduce errors into the measurement of oxygen consumption (VO2) with indirect calorimetry.DesignNonrandomized, controlled trial.SettingExperimental laboratory.SubjectsTen healthy, anesthetized mongrel dogs, weighing 8 to 12 kg.InterventionsData were recorded at seven levels of flow, from 0 to 12 L/min in excess of minute ventilation, through a continuous breathing circuit. Data were recorded at five levels of tracheal tube cuff leak from 0% to 40% of inspiratory minute volume.Measurements And Main ResultsVO2 was measured using an indirect calorimeter with constant internal gas flow and calculated from results of blood gas analysis, cooximetry, and thermodilution cardiac output determinations at all levels of continuous breathing circuit flow and cuff leak. BP, heart rate, respiratory rate, arterial and mixed venous blood gases, and body temperature were measured to assess stability of cardiopulmonary function. Continuous breathing circuit flow did not affect the accuracy of indirect calorimetry until the total flow reached a critical value (11.5 L/min) that was slightly below the internal flow constant of the metabolic monitor (12.4 L/min). At higher circuit flows, measured VO2 decreased in a linear fashion, while calculated VO2 remained unchanged. Above the critical flow, the error of indirect calorimetry correlated significantly only with the total circuit flow (r2 = .64), not with the exhaled concentration of CO2 (r2 = .005) or the inspiratory-expiratory oxygen difference (r2 = .004). The continuous flow rate at the critical circuit flow was 66 +/- 15% of the subjects' peak inspiratory flow. Increasing tracheal tube cuff leak produced a progressive decrease in measured VO2 but not in calculated VO2. The difference between measured and calculated VO2 was linearly related to the magnitude of the leak (r2 = .56), and was statistically significantly larger at all levels of cuff leak, when compared with measurements during complete cuff seal.ConclusionsAn indirect calorimeter in which measurement of VO2 is based on internal constant flow rather than spirometry can be used to accurately measure VO2 from a continuous-flow breathing circuit, if the total circuit flow is less than the internal flow. This limitation may restrict the use of continuous flow to a level below the subject's peak inspiratory flow. The accuracy of indirect calorimetry cannot be guaranteed for any amount of tracheal tube cuff leak.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.