Number of RBC units and rate of transfusionto anemic HIV-positive patients assigned to receiveWBC-reduced or non-WBC-reduced RBCs: the viral activation transfusion study experience.
- M E Brecher, D J Triulzi, S F Assmann, and Viral Activation Transfusion Study.
- Transfusion Medicine Service, University of North Carolina, Chapel Hill, North Carolina 27514, USA. brecher@med.unc.edu
- Transfusion. 2001 Jun 1; 41 (6): 794-8.
BackgroundIt is known that the use of filtration to reduce WBCs in RBC units is associated with a 6- to 15-percent loss of RBCs. It is not known if the use of such WBC-reduced RBCs results in an increased need for RBC units or in the transfusion of more units per year to patients with anemia.Study Design And MethodsIn the multicenter Viral Activation Transfusion Study (VATS), anemic HIV-positive patients were randomly assigned to receive either WBC-reduced or non-WBC-reduced RBCs. The number of RBC units transfused per patient and the rate of RBC use were studied. All RBC units given after the enrollment transfusion were counted, until the end of follow-up or the occurrence of bleeding (receiving >5 RBCs within 2 consecutive days).ResultsAs expected, the WBC-reduced RBC units in VATS were lighter in weight than the non-WBC-reduced units (median weight: WBC-reduced, 300 g; non-WBC-reduced, 330 g; p<0.0001). After the enrollment transfusion, 258 WBC-reduced arm patients received 1279 units of RBCs (average, 5.0 units/patient, median, 2 units) while 262 patients in the non-WBC-reduced arm received 1111 RBCs (4.2 units/patient; median, 2 units). The number of units transfused for anemia was slightly greater in the WBC-reduced arm, but the difference was not significant (p = 0.41). Similarly, the rate of RBC use was somewhat higher in the WBC-reduced arm, but the difference was not significant (p = 0.14). The median was 2.3 units per patient per year of follow-up in the WBC-reduced arm; the median in the non-WBC-reduced arm was 1.2 units.ConclusionThis study confirms that WBC-reduced RBC units are significantly lighter in weight than non-WBC-reduced RBCs. However, in the setting of a large, randomized, blinded study of transfusion for anemia, the smaller size of the WBC-reduced RBC units had no significant effect on the number of RBC units transfused or on the rate at which RBC units were used. In this study, the frequency of blood transfusion may have had a greater relationship to the frequency of routine, scheduled appointments or transfusion orders for a specified Hb trigger than to the actual Hb content of the unit.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.