- Monique Brink, Frank de Lange, Luuk J Oostveen, Helena M Dekker, Digna R Kool, Jaap Deunk, Michael J R Edwards, Cornelis van Kuijk, Richard L Kamman, and Johan G Blickman.
- Department of Diagnostic Imaging, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands. M.Brink@rad.umcn.nl
- Radiology. 2008 Nov 1; 249 (2): 661-70.
PurposeTo evaluate the effect of arm position on image quality and effective radiation dose in an automatic exposure-controlled (AEC) multidetector thoracoabdominal computed tomography (CT) protocol in trauma patients.Materials And MethodsThis retrospective study of the data of 177 trauma patients (117 male; median age, 39 years) was approved by the institutional ethics board, with informed patient consent waived. Patients underwent scanning by using an AEC 16-detector thoracoabdominal CT protocol in which both arms were raised above the shoulder region (standard-position group, 132 patients), one arm was raised and the other was down (one-arm group, 27 patients), or both arms were down (two-arm group, 18 patients). Objective and subjective image quality was assessed. Individual effective radiation dose was calculated from the effective tube current-time product per exposed section. For this purpose, section location-dependent conversion factors were derived by using a CT dosimetry calculator. The effect of arm position on effective dose was quantified by using linear regression analysis with correction for patient volume and attenuation.ResultsCompared with the image quality in the standard-position group, the image quality in the one- and two-arm groups was decreased but within acceptable diagnostic limits. The median corrected effective dose in the standard-position group was 18.6 mSv; the dose in the one-arm group was 18% (95% confidence interval: 11%, 25%) higher than this, and that in the two-arm group was 45% (95% confidence interval: 34%, 57%) higher.ConclusionOmitting arm raising results in lower but acceptable image quality and a substantially higher effective radiation dose. Hence, effort should be made to position the arms above the shoulder when scanning trauma patients. Clinical trial registration no. NCT00228111.(c) RSNA, 2008.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.