-
- Christine N McMillen, Stephen Adu-Yeboah, Elisabeth Kagarise, Rebecca L Morton, Basak Yuce, and F Herbert Douce.
- Division of Respiratory Care, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio. Respiratory Therapy Division, School of Health and Rehabilitation Sciences, College of Medicine, The Ohio State University, Columbus, Ohio. cmcmillen.64@gmail.com.
- Respir Care. 2015 Apr 1;60(4):513-6.
BackgroundTrue arterial blood samples are essential in making clinical decisions for respiratory patients. Previous studies using only the Portex Pro-Vent arterial sampler have shown a significant difference between arterial and venous filling times. The goal of this study was to determine whether there is a statistically significant difference between sampler filling times measured at a normal mean arterial pressure among multiple arterial samplers with plungers and to determine whether there is a statistically significant difference in filling times between venous and normal mean arterial pressures for a sampler without a plunger.MethodsWe assembled an extracorporeal laboratory model to circulate a synthetic compound composed of 0.9% sodium chloride solution and Life/form artificial blood, and we used hemostats to create pressures within the circuit. We randomly selected samplers and measured the filling times of 4 arterial samplers with plungers at a normal mean arterial pressure (93 ± 1 mm Hg). We also measured the filling time of one arterial sampler without a plunger at a normal mean arterial pressure and at a simulated venous pressure (9 ± 2 mm Hg). We used the Kruskal-Wallis one-way analysis of variance to compare arterial filling times in samplers, and we used a t test for independent samples to compare venous and arterial filling times in the sampler without a plunger.ResultsThere was a statistically significant difference between sampler filling times among the 4 arterial samplers with a plunger (P < .001). There was a statistically significant difference between arterial and venous pressure filling times for the sampler without a plunger (P < .001).ConclusionsAlthough there was a statistically significant difference between arterial filling times among various samplers with plungers, the difference was < 1 s and was not deemed clinically important. Regardless of the sampler brand being used, respiratory therapists and other clinicians performing arterial punctures can use sampler filling time to identify a successful arterial puncture while drawing blood.Copyright © 2015 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.