    IntroductionWe evaluated whether automated anesthesia information systems can be used to calculate reference limits (population-based "normal values") for vital signs. We considered four populations of women undergoing cesarean section: healthy under spinal anesthesia, healthy under general anesthesia, pre-eclamptic/eclamptic under spinal anesthesia, and pre-eclamptic/eclamptic under general anesthesia.MethodsReference limits were calculated for each of the study populations by determination of percentiles for: minimum heart rate, maximum heart rate, minimum arterial oxyhemoglobin saturation (SaO2), minimum mean arterial pressure (MAP), maximum MAP, decrease in MAP, and increase in MAP.ResultsThere was one adverse anesthetic outcome among the 1,300 women in the study; the woman sustained a post-dural puncture headache. The 5th percentiles of SaO2 were at least 95% saturation under spinal versus 90% under general. Under spinal anesthesia, 95th percentiles for decreases in MAP from baseline were 63 mmHg for healthy and 75 mmHg for pre-eclamptic/eclamptic women. Under general anesthesia, the 95th percentiles for maximum MAP were 161 and 177 mmHg, respectively. Two women of the 1,300 patients experienced simultaneously a minimum SaO2 < 92% and minimum MAP < 50 mmHg.DiscussionAutomated anesthesia information systems can be used to determine reference limits for vital signs during anesthesia. Reference limits may play a role in malpractice cases when an expert claims that care by an anesthesiologist was sub-standard as shown by vital signs that were not maintained within the normal range during the critical portions of an anesthetic. Automated anesthesia information systems may enhance expert witnesses' clinical judgment.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…