    Cardiopulmonary resuscitation with a hydraulic-pneumatic band.

    • H Halperin, R Berger, N Chandra, M Ireland, C Leng, A Lardo, and N Paradis.
    • Department of Medicine, The Johns Hopkins University School of Medicine, Baltimore, MD, USA.
    • Crit. Care Med. 2000 Nov 1; 28 (11 Suppl): N203-6.

    AbstractImproved blood flow during cardiopulmonary resuscitation (CPR) has been shown to enhance survival from cardiac arrest. Chest compression with a circumferential pneumatic vest enhances blood flow, but the size, weight, and energy consumption of the inflation system limit its portability and, thereby, have made clinical studies difficult. The purpose of this investigation was to study an improved circumferential chest compression device that uses a constricting band that is pneumatically actuated. The constricting band applies its force to a hydraulic cushion that contacts the anterior and lateral aspects of the chest. The hydraulic cushion transfers the circumferential constriction to inward force. CPR was performed on subjects 5 mins after induction of ventricular fibrillation, with the hydraulic-pneumatic band system (HB-CPR), with a pneumatic vest system (PV-CPR), and with standard manual CPR (S-CPR), each done for 2 mins in randomized order. Aortic and right atrial pressures were measured with micromanometers. Coronary perfusion pressure was calculated as the mean difference between the aortic and right atrial pressures during the release phase of chest compression. Aortic pressure and coronary perfusion pressure with HB-CPR and PV-CPR were improved over S-CPR, and HB-CPR produced comparable pressures to those of PV-CPR. The system for performing HB-CPR, however, was substantially lighter (10 vs. 50 kg) and consumed less energy (300 vs. 1000 watts) than that for PV-CPR. Thus, HB-CPR appears to produce a similar improvement in hemodynamics over S-CPR as PV-CPR but may be more portable than PV-CPR. Therefore, HB-CPR may allow larger scale testing of circumferential chest compression approaches.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.