• J Minim Invasive Gynecol · Sep 2008

    Thermal conduction, compression, and electrical current--an evaluation of major parameters of electrosurgical vessel sealing in a porcine in vitro model.

    • Christian W Wallwiener, Taufiek K Rajab, Wolfgang Zubke, Keith B Isaacson, Markus Enderle, Daniel Schäller, and Markus Wallwiener.
    • University Hospital rechts der Isar, Technical University of Munich, Munich, Germany. cwallwiener@gmx.net
    • J Minim Invasive Gynecol. 2008 Sep 1; 15 (5): 605-10.

    AbstractBipolar vessel sealing is pivotal in laparoscopic hemostasis. However, major coaptive desiccation parameters have yet to be investigated in detail. The current investigation aims to study the impact of compressive pressure, thermal conduction, and electrical current effects on seal quality in a randomized, controlled experimental trial in an in vitro porcine model of vessel sealing. A total of 106 porcine vessels were sealed with either bipolar current or thermal conduction. Compressive pressure on the sealing site and maximum temperature were varied and monitored. Additionally, the longitudinal vessel tension was measured. The burst pressure of the resulting seal was determined as an indicator of seal quality. In bipolar coaptation, seal quality depends on the compressive pressure applied to the coagulation site in both arteries and veins. The optimal pressure interval was around 270 mN/mm2 for arteries and 200 mN/mm2 for veins. Deviation from these optimal pressures towards low and high extremes led to significantly fewer successful seals. We also found that both maximum coaptation temperature and vessel shrinking correlated with the seal quality. This correlation was reciprocal in arteries and veins. Thermal conduction alone was less successful than sealing by bipolar current. Therefore, compressive pressure during coaptation determines the seal quality. Upper and lower pressure boundaries for safe coaptation exist for both arteries and veins. Vessel sealing by thermal conduction without electrical current effects is possible but represents a less effective method for coaptation. These findings have implications for the rational design of new electrosurgical instruments.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…