-
- Thomas Bitter, Nina Westerheide, Mohammed Sajid Hossain, Roman Lehmann, Christian Prinz, Astrid Kleemeyer, Dieter Horstkotte, and Olaf Oldenburg.
- Department of Cardiology, Heart and Diabetes Centre NRW, Ruhr University Bochum, Georgstrasse 11, D-32545 Bad Oeynhausen, Germany.
- Thorax. 2011 May 1; 66 (5): 402-7.
BackgroundSleep disordered breathing is common and of prognostic significance in patients with congestive heart failure (CHF). Complex sleep apnoea (complexSA) is defined as the emergence of central sleep apnoea during continuous positive airway pressure (CPAP) treatment in patients with obstructive sleep apnoea (OSA). This study aims to determine the prevalence and predictors for complexSA in patients with CHF with OSA, and to assess the effects of treatment with adaptive servoventilation.Methods192 patients with CHF (left ventricular ejection fraction (LVEF) ≤45%, New York Heart Association (NYHA) class ≥2) and OSA (apnoea-hypopnoea index (AHI) ≥15) were investigated using echocardiography, cardiopulmonary exercise testing, measurement of hyperoxic, hypercapnic ventilatory response, 6 min walk test and measurement of N-terminal pro-brain natriuretic peptide (NT-proBNP) prior to CPAP introduction. If patients demonstrated complexSA (AHI >15/h with <10% obstructive events) during CPAP titration, adaptive servoventilation was introduced and the investigations were repeated at 3 monthly follow-up visits.ResultsComplexSA developed in 34 patients (18%) during CPAP titration. After adjustment for demographic and cardiac parameters, measures of CO(2) sensitivity (higher hyperoxic, hypercapnic ventilatory response) were independently associated with complexSA. Patients using adaptive servoventilation had improved AHI, NYHA class, NT-proBNP concentration, LVEF, hyperoxic, hypercapnic ventilatory response, oxygen uptake during cardiopulmonary exercise testing and the relationship between minute ventilation and the rate of CO(2) elimination (VE/Vco(2) slope) at last individual follow-up (14±4 months).ConclusionThere is a high prevalence of complexSA in patients with OSA and CHF, and those who develop complexSA have evidence of higher respiratory controller gain before application of CPAP. Treatment with adaptive servoventilation effectively suppressed complexSA and had positive effects on cardiac function and respiratory stability.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.