- J Petersen, J H Delaney, M T Brakstad, R K Rowbotham, and C M Bagley.
- Department of Oncology, Northwest Hospital, Northwest Cancer Center, Seattle, Washington 98133, USA.
- Am. J. Surg. 1999 Jul 1; 178 (1): 38-41.
BackgroundSilicone venous access devices (VADs) are commonly used for multiple intravenous infusions and blood sampling in chronically ill patients, particularly cancer patients. These devices are susceptible to malfunctions most commonly characterized by difficulty infusing fluids or withdrawing blood. We hypothesized that the incidence of such malfunctions is primarily related to the position of the catheter tip relative to the superior vena cava/right atrial junction.MethodsWe reviewed medical records for 141 patients in whom silicone venous access devices were used. Chest radiographs obtained following catheter insertion were reviewed by a single radiologist to rule out pneumothorax and determine the position of the catheter tip. Other potential factors included in the analysis were catheter brand, the vein into which the catheter was inserted, and the side (right or left). A malfunction was defined as resistance to flushing or infusion of a substance, complete inability to infuse a substance, resistance to blood aspiration attempts, or absence of blood return with aspiration, occurring any time during which the catheter was in place. Multiple logistic regression was used to determine which factor(s) most strongly predicted catheter malfunction.ResultsCatheter tip location was the only factor that was statistically predictive of malfunctions (coefficient 0.842, P < 0.001). A significant increase in malfunctions was observed in cases where the catheter tip was located greater than 4 cm superior to the junction of the right atrium and the superior vena cava (z-test of proportions, P = 0.003). Malfunctions were minimized in those cases where the catheter tip was located in the right atrium.ConclusionsThese results indicate that malfunctions can be minimized in silicone venous access catheters by locating the catheter tip as close to the superior vena cava/right atrial junction as possible, or slightly inside the right atrium. To ensure proper location of the catheter tip, placement should be performed under fluoroscopy, and a radiograph should be obtained immediately following placement, with the patient in the upright position.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.