J Bone Joint Surg Am · Sep 2003
Occupational exposure from common fluoroscopic projections used in orthopaedic surgery.
- Nicholas Theocharopoulos, Kostas Perisinakis, John Damilakis, George Papadokostakis, Alexander Hadjipavlou, and Nicholas Gourtsoyiannis.
- University Hospital of Iraklion, Crete, Greece.
- J Bone Joint Surg Am. 2003 Sep 1; 85-A (9): 1698-703.
BackgroundPersonnel assisting in or performing fluoroscopically guided procedures may be exposed to high doses of radiation. Accurate occupational dosimetric data for the orthopaedic theater staff are of paramount importance for practicing radiation safety.MethodsFluoroscopic screening was performed on an anthropomorphic phantom with use of four projections common in image-guided orthopaedic surgery. The simulated projections were categorized, according to the imaged anatomic area and the beam orientation, as (1) hip joint posterior-anterior, (2) hip joint lateral cross-table 45 degrees, (3) lumbar spine anterior-posterior, and (4) lumbar spine lateral 90 degrees. The scattered air kerma rate was measured on a grid surrounding the operating table. For each grid point, the effective dose, eye lens dose, and face skin dose values, normalized over the tube dose area product, were derived. For the effective dose calculations, three radiation protection conditions were considered: (1) with the exposed personnel using no protection measures, (2) with the exposed personnel wearing a 0.5-mm lead-equivalent protective apron, and (3) with the exposed personnel wearing both an apron and a thyroid collar. Maximum permissible workloads for typical hip, spine, and kyphoplasty procedures were derived on the basis of compliance with effective dose, eye lens dose, and skin dose limits.ResultsWe found that the effective dose, eye lens dose, and face skin dose to an orthopaedic surgeon wearing a 0.5-mm lead-equivalent apron will not exceed the corresponding limits if the dose area product of the fluoroscopically guided procedure is <0.38 Gy m (2). When protective eye goggles are also worn, the maximum permissible dose area product increases to 0.70 Gy m (2), while the additional use of a thyroid shield allows a workload of 1.20 Gy m (2). The effective dose to the orthopaedic surgeon working tableside during a typical hip, spine, kyphoplasty procedure was 5.1, 21, and 250 micro Sv, respectively, when a 0.5-mm lead-equivalent apron alone was used. The additional use of a thyroid shield reduced the effective dose to 2.4, 8.4, and 96 micro Sv per typical hip, spine, and kyphoplasty procedure, respectively.ConclusionsThe levels of occupational exposure vary considerably with the type of fluoroscopically assisted procedure, staff positioning, and the radiation protection measures used. The data presented in the current study will allow for accurate estimation of the occupational dose to orthopaedic theater personnel.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.