• Respir Physiol Neurobiol · Mar 2007

    Review Meta Analysis

    Arterial versus capillary blood gases: a meta-analysis.

    • Gerald S Zavorsky, Jiguo Cao, Nancy E Mayo, Rina Gabbay, and Juan M Murias.
    • Department of Anesthesia, McGill University Health Center, Montreal, Quebec, Canada. gerald.zavorsky@mcgill.ca <gerald.zavorsky@mcgill.ca>
    • Respir Physiol Neurobiol. 2007 Mar 15; 155 (3): 268-79.

    AbstractA meta-analysis determined whether capillary blood gases accurately reflect arterial blood samples. A mixed effects model was used on 29 relevant studies obtained from a PubMed/Medline search. From 664 and 222 paired samples obtained from the earlobe and fingertip, respectively, earlobe compared to fingertip sampling shows that the standard deviation of the difference is about 2.5x less (or the precision is 2.5x better) in resembling arterial PO(2) over a wide range of arterial PO(2)'s (21-155 mm Hg ). The lower the arterial PO(2), the more accurate it is when predicting arterial PO(2) from any capillary sample (p<0.05). However, while earlobe sampling predicts arterial PO(2) (adjusted r(2)=0.88, mean bias=3.8 mm Hg compared to arterial), fingertip sampling does not (adjusted r(2)=0.48, mean bias=11.5 mm Hg compared to arterial). Earlobe sampling is slightly more accurate compared to fingertip sampling in resembling arterial PCO(2) (arterial versus earlobe, adjusted r(2)=0.94, mean bias=1.9 mm Hg ; arterial versus fingertip, adjusted r(2)=0.95, mean bias=2.2 mm Hg compared to arterial) but both sites can closely reflect arterial PCO(2) (880 total paired samples, range 10-114 mm Hg ). No real difference between sampling from the earlobe or fingertip were found for pH as both sites accurately reflect arterial pH over a wide range of pH (587 total paired samples, range 6.77-7.74, adjusted r(2)=0.90-0.94, mean bias=0.02). In conclusion, sampling blood from the fingertip or earlobe (preferably) accurately reflects arterial PCO(2) and pH over a wide range of values. Sampling blood, too, from earlobe (but never the fingertip) may be appropriate as a replacement for arterial PO(2), unless precision is required as the residual standard error is 6 mm Hg when predicting arterial PO(2) from an earlobe capillary sample.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…