Comparative Study
Evaluating Osseointegration into a Deeply Porous Titanium Scaffold: A Biomechanical Comparison with PEEK and Allograft.
- Richard D Guyer, Jean-Jacques Abitbol, Donna D Ohnmeiss, and Chang Yao.
- Texas Back Institute, Plano, TX.
- Spine. 2016 Oct 1; 41 (19): E1146-E1150.
Study DesignThis was a biomechanical push-out testing study using a porcine model.ObjectiveThe purpose was to evaluate the strength of implant-bone interface of a porous titanium scaffold by comparing it to polyetheretherketone (PEEK) and allograft.Summary Of Background DataOsseointegration is important for achieving maximal stability of spinal fusion implants and it is desirable to achieve as quickly as possible. Common PEEK interbody fusion implants appear to have limited osseointegration potential because of the formation of fibrous tissue along the implant-bone interface. Porous, three-dimensional titanium materials may be an option to enhance osseointegration.MethodsUsing the skulls of two swine, in the region of the os frontale, 16 identical holes (4 mm diameter) were drilled to 10 mm depth in each skull. Porous titanium, PEEK, and allograft pins were press fit into the holes. After 5 weeks, animals were euthanized and the skull sections with the implants were cut into sections with each pin centered within a section. Push-out testing was performed using an MTS machine with a push rate of 6 mm/min. Load-deformation curves were used to compute the extrinsic material properties of the bone samples. Maximum force (N) and shear strength (MPa) were extracted from the output to record the bonding strength between the implant and surrounding bone. When calculating shear strength, maximum force was normalized by the actual implant surface area in contact with surrounding bone.ResultsMean push-out shear strength was significantly greater in the porous titanium scaffold group than in the PEEK or allograft groups (10.2 vs. 1.5 vs. 3.1 MPa, respectively; P < 0.05).ConclusionThe push-out strength was significantly greater for the implants with porous titanium coating compared with the PEEK or allograft. These results suggest that the material has promise for facilitating osseointegration for implants, including interbody devices for spinal fusion.Level Of EvidenceN/A.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.