• Respiratory care · May 2015

    Carbon Dioxide Elimination and Oxygen Consumption in Mechanically Ventilated Children.

    • Craig D Smallwood, Brian K Walsh, Lori J Bechard, and Nilesh M Mehta.
    • Division of Critical Care Medicine, Department of Anesthesiology, Perioperative and Pain Medicine Harvard Medical School, Boston, Massachusetts. craig.smallwood@childrens.harvard.edu.
    • Respir Care. 2015 May 1;60(5):718-23.

    BackgroundAccurate measurement of carbon dioxide elimination (V̇CO2 ) and oxygen consumption (V̇O2 ) at the bedside may help titrate nutritional and respiratory support in mechanically ventilated patients. Continuous V̇CO2 monitoring is now available with many ventilators. However, because normative data are sparsely available in the literature, we aimed to describe the range of V̇CO2 and V̇O2 values observed in mechanically ventilated children. We also aimed to examine the characteristics of V̇CO2 values that are associated with standard steady state (5-min period when V̇CO2 and V̇O2 variability are < 10%).MethodsMechanically ventilated patients who underwent indirect calorimetry testing were eligible for inclusion, and subjects who achieved standard steady state were included. Normalized V̇CO2 and V̇O2 values (mL/kg/min) were modeled against subject height, and correlation coefficients were computed to quantify the goodness of fit. A steady-state definition using only V̇CO2 was developed (V̇CO2 variability of < 5% for a 5-min period) and tested against standard steady state using sensitivity and specificity.ResultsSteady-state data from 87 indirect calorimetry tests (in 70 subjects) were included. For age groups < 0.5, 0.5-8, and > 8 y, the mean V̇CO2 values were 7.6, 5.8, and 3.5 mL/kg/min. Normalized V̇CO2 and V̇O2 values were inversely related to subject height and age. The relationships between normalized gas exchange values and height were demonstrated by the models: V̇CO2 = 115 × (height in cm)(-0.71) (R = 0.61, P < .001) and V̇O2 = 130 × (height in cm)(-0.72) (R = 0.61, P < .001). Steady-state V̇CO2 predicted standard steady state (sensitivity of 0.84, specificity of 1.0, P < .01).ConclusionsV̇CO2 and V̇O2 measurements correlated with subject height and age. Smaller and younger subjects produced larger amounts of CO2 and consumed more O2 per unit of body weight. The use of a 5-min period when V̇CO2 varied by < 5% predicted standard steady state. Our observations may facilitate greater utility of V̇CO2 at the bedside in the pediatric ICU and thereby extend the benefits of metabolic monitoring to a larger group of patients.Copyright © 2015 by Daedalus Enterprises.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.