• Circ Heart Fail · Sep 2014

    Comparative Study

    Bridge-to-decision therapy with a continuous-flow external ventricular assist device in refractory cardiogenic shock of various causes.

    • Hiroo Takayama, Lori Soni, Bindu Kalesan, Lauren K Truby, Takeyoshi Ota, Sophia Cedola, Zain Khalpey, Nir Uriel, Paolo Colombo, Donna M Mancini, Ulrich P Jorde, and Yoshifumi Naka.
    • From the Departments of Surgery (H.T., L.S., B.K., L.K.T., T.O., S.C., Z.K., Y.N.) and Medicine (N.U., P.C., D.M.M., U.P.J.), Columbia University Medical Center, New York, NY. hirofu2@hotmail.com.
    • Circ Heart Fail. 2014 Sep 1; 7 (5): 799-806.

    BackgroundMortality for refractory cardiogenic shock remains high. In this patient cohort, there have been mixed results in mechanical circulatory support device use as a bridge-to-decision therapy. We evaluated a continuous-flow external ventricular assist device (VAD), CentriMag VAD (Thoratec Corp., Pleasanton, CA), in patients with various causes of refractory cardiogenic shock.Methods And ResultsThis is a retrospective review of adult patients who underwent surgical CentriMag VAD insertion as bridge-to-decision therapy. From January 2007 through June 2012, 143 patients received CentriMag VAD. The cause of refractory cardiogenic shock was failure of medical management in 71 patients, postcardiotomy shock in 37, graft failure post-heart transplantation in 22, and right ventricular failure post-implantable left VAD in 13. Mean age was 52±16 years, and 71% were in INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 1. Among 158 device runs, device configuration was BiVAD in 67%, isolated right VAD in 26%, and isolated left VAD in 8%. Median duration of support was 14 days (interquartile range, 8-26). Survival was 69% at 30 days and 49% at 1 year. The next destination after the CentriMag VAD was myocardial recovery in 30%, device exchange to an implantable VAD in 15%, and heart transplantation in 18%. The failure of medical management and the graft failure post-heart transplantation groups had higher 30-day survival compared with the postcardiotomy shock group. Major bleeding events occurred in 33% and cerebrovascular accidents in 14%. There was no CentriMag pump failure or thrombosis.ConclusionsBridge-to-decision therapy with CentriMag VAD is feasible in a variety of refractory cardiogenic shock settings. Patients with postcardiotomy shock have inferior survival.© 2014 American Heart Association, Inc.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…