Anesthesia and analgesia · Oct 2010
Randomized Controlled Trial Comparative StudyA long-term clinical evaluation of autoflow during assist-controlled ventilation: a randomized controlled trial.
- Sigismond Lasocki, Françoise Labat, Gaetan Plantefeve, Mathieu Desmard, and Hervé Mentec.
- Réanimation Chirurgicale, CHU Bichat, 46 rue Henri Huchard, 75018 Paris, France. sigismond@lasocki.com
- Anesth. Analg. 2010 Oct 1; 111 (4): 915-21.
BackgroundMany new mechanical ventilation modes are proposed without any clinical evaluation. "Dual-controlled" modes, such as AutoFlow™, are supposed to improve patient- ventilator interfacing and could lead to fewer alarms. We performed a long-term clinical evaluation of the efficacy and safety of AutoFlow during assist-controlled ventilation, focusing on ventilator alarms.MethodsForty-two adult patients, receiving mechanical ventilation for more than 2 days with a Dräger Evita 4 ventilator were randomized to conventional (n = 21) or AutoFlow (n = 21) assist-controlled ventilation. Sedation was given using a nurse-driven protocol. Ventilator-generated alarms were exhaustively recorded from the ventilator logbook with a computer. Daily blood gases and ventilation outcome were recorded.ResultsA total of 403 days of mechanical ventilation were studied and 45,022 alarms were recorded over a period of 8074 hours. The course of respiratory rate, minute ventilation, Fio(2), positive end-expiratory pressure, Pao(2)/Fio(2), Paco(2), and pH and doses and duration of sedation did not differ between the 2 groups. Outcome (duration of mechanical ventilation, ventilator-associated pneumonia, course of Sequential Organ Failure Assessment score, or death) was not different between the 2 groups. The number of alarms per hour was lower with AutoFlow assist-controlled ventilation: 3.3 [1.5 to 17] versus 9.1 [5 to 19], P < 0.0001 (median [quartile range]). In multivariate analysis, a low alarm rate was associated with activation of AutoFlow and a higher midazolam dose.ConclusionsThis first long-term clinical evaluation of the AutoFlow mode demonstrated its safety with regard to gas exchange and patient outcome. AutoFlow also allowed a very marked reduction in the number of ventilator alarms.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.