• J Shoulder Elbow Surg · Dec 2015

    Randomized Controlled Trial

    Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.

    • Benedikt Schliemann, Robert Seifert, Steffen B Rosslenbroich, Christina Theisen, Dirk Wähnert, Michael J Raschke, and Andre Weimann.
    • Department of Trauma, Hand and Reconstructive Surgery, University Hospital Münster, Münster, Germany. Electronic address: benedikt.schliemann@gmail.com.
    • J Shoulder Elbow Surg. 2015 Dec 1; 24 (12): 1968-73.

    BackgroundShear forces at the bone-implant interface lead to a loss of reduction after locking plate fixation of proximal humeral fractures. The aim of the study was to analyze the roles of medial support screws and screw augmentation in failure loads and motion at the bone-implant interface after locking plate fixation of proximal humeral fractures.MethodsUnstable 3-part fractures were simulated in 6 pairs of cadaveric humeri and were fixed with a DiPhos-H locking plate (Lima Corporate, Udine, Italy). An additional medial support screw was implanted in 1 humerus of every donor. The opposite humerus was stabilized with a medial support screw and additional bone cement augmentation of the 2 anteriorly directed head screws. Specimens were loaded in the varus bending position. Stiffness, failure loads, plate bending, and the motion at the bone-implant interface were evaluated using an optical motion capture system.ResultsThe mean load to failure was 669 N (standard deviation [SD], 117 N) after fixation with medial support screws alone and 706 N (SD, 153 N) after additional head screw augmentation (P = .646). The initial stiffness was 453 N/mm (SD, 4.16 N/mm) and 461 N/mm (SD, 64.3 N/mm), respectively (P = .594). Plate bending did not differ between the 2 groups. However, motion at the bone-implant interface was significantly reduced after head screw augmentation (P < .05).ConclusionThe addition of bone cement to augment anteriorly directed head screws does not increase stiffness and failure loads but reduces motion at the bone-implant interface. Thus, the risk of secondary dislocation of the head fragment may be reduced.Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.