• Clinical endocrinology · May 2000

    Comparative Study

    Low-dose (1 microgram) adrenocorticotrophin (ACTH) stimulation as a screening test for impaired hypothalamo-pituitary-adrenal axis function: sensitivity, specificity and accuracy in comparison with the high-dose (250 microgram) test.

    • K Tordjman, A Jaffe, Y Trostanetsky, Y Greenman, R Limor, and N Stern.
    • Institute of Endocrinology, Tel Aviv-Sourasky Medical Center, Tel Aviv University Sackler Faculty of Medicine, Tel Aviv, Israel. ktordjma@im.wustl.edu
    • Clin. Endocrinol. (Oxf). 2000 May 1; 52 (5): 633-40.

    ObjectiveWe have shown previously that in contrast to the standard high-dose 250-microgram ACTH test, a low-dose 1-microgram ACTH stimulation test correctly identified all patients with pituitary disease who had impaired hypothalamo-pituitary-adrenal (HPA) function. In this study we further compared the performances of these two tests as screening procedures for possible HPA impairment.DesignA comparison of the 1-microgram and the 250-microgram ACTH stimulation tests in healthy controls and in patients with pituitary disease whose HPA axis status was characterized formally by a gold standard test.SubjectsA total of 89 subjects were investigated: 27 healthy normal controls, 43 patients with pituitary disease and normal HPA function, and 19 patients with various pituitary diseases and impaired HPA function.MeasuresAll 89 subjects underwent stimulation with 1 microgram ACTH; 80 also underwent the high-dose 250-microgram ACTH test. A receiver operating characteristic analysis (ROC) was performed to compare the tests.ResultsUsing a stimulated cortisol > 500 nmol/l as the criterion for a normal response, the 1-microgram ACTH stimulation identified 18 of the 19 subjects with impaired HPA function (94.7% sensitivity with a likelihood ratio of 0.0588 for a negative test). In contrast, 15/16 passed the high-dose test (a 6.2% sensitivity with a likelihood ratio of 0.875 for a negative test). All normal controls, and 36/43 patients with preserved HPA function, passed the 1-microgram ACTH test (90% specificity). This degree of accuracy was unrivalled by the high dose test at all the cut-off levels considered.ConclusionsMore sensitive and accurate, the low-dose 1-microgram ACTH test is as simple and safe as the standard 250-microgram test. We suggest it should replace it in screening for adrenal insufficiency.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…