• J. Pediatr. Surg. · May 1997

    Evaluation of an extracorporeal membrane oxygenation system using a nonporous membrane oxygenator and a new method for heparin coating.

    • Y Kitano, M Takata, K Miyasaka, N Sasaki, Q Zhang, D Liu, and Y Tsuchida.
    • Department of Pediatric Surgery, University of Tokyo, Japan.
    • J. Pediatr. Surg. 1997 May 1; 32 (5): 691-7.

    AbstractA new heparin binding method was applied to a miniature extracorporeal membrane oxygenation (ECMO) system with a nonporous membrane oxygenator (the priming volume, 45 mL; the membrane surface area, 0.4 m2; maximal flow rate, 2 L/min) that is resistant to plasma leakage. The authors evaluated the stability of the immobilized heparin in vitro and the feasibility of this system in animals. Samples of hollow fibers and tubing were rinsed at 40 degrees C for 4 days in normal saline, Ringer's lactate, and 1 mol/L NaCl solution. Heparin activities on hollow fibers after rinsing were 99 +/- 2.3% (mean +/- SD), 96 +/- 3.9%, and 93 +/- 2.0% of the control in each solution, while those of the tubing were 87 +/- 4.1%, 86 +/- 3.1%, and 76 +/- 8.6%, respectively. Veno-arterial ECMO using this heparin-coated system was performed on five beagles (8 to 12 kg) for 10 hours. Neither major thrombus formation nor plasma leakage was detected during the procedure in spite of a low flow rate (300 mL/min) and a reduced activated clotting time (mean, 128 seconds). Platelets decreased to 52% of the control (P < .01) at 1 hour, but no progressive decrease was seen thereafter. Antithrombin-III decreased (P < .01) and thrombin/antithrombin III complex increased (P < .05 at 4 hours and P < .01 at 6, 8, and 10 hours) during bypass, but the changes of fibrinogen and fibrinopeptide A were not significant. Fibrinogen/fibrin degeneration products, fibrinopeptide B beta 15-42, and plasma-free hemoglobin levels did not rise significantly. O2 transfer of the oxygenators at a flow rate of 300 mL/min were 12.3 +/- 0.4 mL/min at 30 minutes, 14.3 +/- 1.2 mL/min at 5 hours, and 14.7 +/- 1.7 mL/min at 10 hours (no statistical difference). Histological examination of the brains and the kidneys showed no evidence of thromboembolic sequela in any of the animals. These results suggest that this new system is a promising device for long-term ECMO in which the amount of systemic heparinization can be reduced with the minimal possibility of plasma leakage.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…