• J Cardiovasc Nurs · Sep 2014

    Novel approach to cardiac alarm management on telemetry units.

    • Deborah A Whalen, Patricia M Covelle, James C Piepenbrink, Karen L Villanova, Charlotte L Cuneo, and Eric H Awtry.
    • Deborah A. Whalen, MSN, MBA, APRN, ANP-BC, FAHA Assistant Professor of Medicine, School of Medicine, Boston University, and Clinical Service Manager, Cardiology, Boston Medical Center, Massachusetts. Patricia M. Covelle, MMHC, RN Director of Critical Care Nursing, Boston Medical Center, Massachusetts. James C. Piepenbrink, BSBME Director of Clinical Engineering, Boston Medical Center, Massachusetts. Karen L. Villanova, BSN, RN Nurse Manager, Boston Medical Center, Massachusetts. Charlotte L. Cuneo, MSN, RN Clinical Instructor, Boston Medical Center, Massachusetts. Eric H. Awtry, MD Associate Professor of Medicine, School of Medicine, Boston University, and Inpatient Clinical Director, Division of Cardiology, Boston Medical Center, Massachusetts.
    • J Cardiovasc Nurs. 2014 Sep 1; 29 (5): E13-22.

    BackgroundGeneral medical-surgical units struggle with how best to use cardiac monitor alarms to alert nursing staff to important abnormal heart rates (HRs) and rhythms while limiting inappropriate and unnecessary alarms that may undermine both patient safety and quality of care. When alarms are more often false than true, the nursing staff's sense of urgency in responding to alarms is diminished. In this syndrome of "clinical alarm fatigue," the simple burden of alarms desensitizes caregivers to alarms. Noise levels associated with frequent alarms may also heighten patient anxiety and disrupt their perception of a healing environment. Alarm fatigue experienced by nurses and patients is a significant problem and innovative solutions are needed.ObjectiveThe purpose of this quality improvement study was to determine variables that would safely reduce noncritical telemetry and monitor alarms on a general medical-surgical unit where standard manufacturer defaults contributed to excessive audible alarms.MethodsMining of alarm data and direct observations of staff's response to alarms were used to identify the self-reset warning alarms for bradycardia, tachycardia, and HR limits as the largest contributors of audible alarms. In this quality improvement study, the alarms for bradycardia, tachycardia, and HR limits were changed to "crisis," requiring nursing staff to view and act on the alarm each time it sounded. The limits for HR were HR low 45 bpm and HR high 130 bpm.ResultsAn overall 89% reduction in total mean weekly audible alarms was achieved on the pilot unit (t = 8.84; P < .0001) without requirement for additional resources or technology. Staff and patient satisfaction also improved. There were no adverse events related to missed cardiac monitoring events, and the incidence of code blues decreased by 50%.ConclusionsAlarms with self-reset capabilities may result in an excess number of audible alarms and clinical alarm fatigue. By eliminating self-resetting alarms, the volume of audible alarms and associated clinical alarm fatigue can be significantly reduced without requiring additional resources or technology or compromising patient safety and lead to improvement in both staff and patient satisfaction.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.