• J. Heart Lung Transplant. · Jan 2014

    Hemolysis: a harbinger of adverse outcome after left ventricular assist device implant.

    • Jennifer A Cowger, Matthew A Romano, Palak Shah, Neha Shah, Vivek Mehta, Jonathan W Haft, Keith D Aaronson, and Francis D Pagani.
    • Division of Cardiovascular Medicine, University of Michigan Health System, Ann Arbor, Michigan. Electronic address: jennifercowger@gmail.com.
    • J. Heart Lung Transplant. 2014 Jan 1; 33 (1): 35-43.

    BackgroundThe clinical relevance of elevated serum markers of hemolysis during left ventricular assist device (LVAD) support has not been fully ascertained.MethodsLactate dehydrogenase (LDH) and serum free hemoglobin (sfHg) values were tallied monthly in 182 patients on HeartMate II (Thoratec, Pleasanton, CA) LVAD support. Peak values for each marker were identified, and 2 hemolysis definitions were applied to the cohort: Hemolysis according to Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) criteria (sfHg > 40 mg/dl with signs/symptoms) and/or hemolysis defined by an LDH ≥ 600 IU/liter (2.5-times the upper limit of laboratory normal). Kaplan-Meier survival free from death, urgent United Network of Organ Sharing 1A transplant for thrombosis, device exchange for thrombosis, and stroke/peripheral embolism was estimated, and Cox hazard ratios (HR) with the 95% confidence interval (95% CI) were calculated. Areas under the receiver-operating characteristic curves (AUCs) for predicting 1-year event-free survival were calculated.ResultsHemolysis occurred in 32 patients (18%) by INTERMACS criteria and in 68 (37%) patients by LDH criteria. Over a median (25(th), 75(th)) support of 427 days (245, 793 days), there were 78 events. One year event-free survival after the onset of INTERMACS-defined hemolysis was 16% ± 8.3% compared with 85% ± 3.2% in non-hemolyzers (HR, 14.7; 95% CI, 7.9-27; AUC 0.70 ± 0.05; p < 0.001; ). One year event-free survival after the onset of LDH-defined hemolysis was 32% ± 7.2% compared with 89% ± 3.2% in those with persistent LDH values < 600 IU/liter (HR, 8.0; 95% CI, 4.4-14; AUC 0.87 ± 0.04; p < 0.001). Patients who met the LDH hemolysis definition had longer times from hemolysis onset to clinical events and larger magnitudes of risk for embolism and device exchange for thrombosis than those with INTERMACS hemolysis.ConclusionsSerum hemolysis marker elevations are associated with increased events in LVAD patients. LDH monitoring provides an earlier diagnosis of adverse events than sfHg, supporting need for a new INTERMACS definition of VAD-associated hemolysis.© 2014 International Society for Heart and Lung Transplantation Published by International Society for the Heart and Lung Transplantation All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…