Randomized Controlled Trial Comparative Study Clinical Trial
Laparoscopic cholecystectomy using abdominal wall retraction. Hemodynamics and gas exchange, a comparison with conventional pneumoperitoneum.
- D W Meijer, B P Rademaker, S Schlooz, W A Bemelman, L T de Wit, J J Bannenberg, T Stijnen, and D F Gouma.
- Working Group Development Surgical Technology, Surgical Division, Academic Medical Centre, IWO-gebouw 1 etage k151, University of Amsterdam, Amsterdam, The Netherlands.
- Surg Endosc. 1997 Jun 1; 11 (6): 645-9.
BackgroundDisadvantages related to CO2 pneumoperitoneum have led to development of the abdominal wall retractor (AWR), a device designed to facilitate laparoscopic surgery without conventional pneumoperitoneum (15 mmHg CO2). We investigated the effects of the AWR on hemodynamics and gas exchange in humans. We also investigated whether the use of an AWR imposed extra technical difficulties for the surgeon. A pilot study revealed that cholecystectomy without low-pressure pneumoperitoneum was technically impossible.MethodsA prospective randomized controlled trial: Twenty patients undergoing laparoscopic cholecystectomy were randomly allocated into group 1: AWR with low-pressure pneumoperitoneum (5 mmHg), or group 2: conventional pneumoperitoneum (15 mmHg).ResultsSurgery using the AWR lasted longer, 72 +/- 16 min (mean +/- SD) vs 50 +/- 18 min compared with standard laparoscopic cholecystectomy. There were no differences between the groups with respect to hemodynamic parameters, although a small reduction of the cardiac output was observed using conventional pneumoperitoneum (from 3.9 +/- 0.7 to 3. 2 +/- 1.1 l/min) and an increase during AWR (from 4.2 +/- 0.9 to 5.2 +/- 1.5 l/min). Peak inspiratory pressures were significantly higher during conventional pneumoperitoneum compared to AWR. A slight decrease in pH accompanied by an increase in CO2 developed during pneumoperitoneum and during the use of the AWR. In both groups arterial PO2 decreased.ConclusionsThe results indicate that the view was impaired during use of the AWR and therefore its use was difficult and time-consuming. Possible advantages of this devices' effects on hemodynamics and ventilatory parameters could not be confirmed in this study.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.