-
J Vet Emerg Crit Care (San Antonio) · Sep 2014
Accuracy of calculated arterial saturation in oxygen in neonatal foals and effects of monitor, sensor, site of sensor placement, and degree of hypoxemia on the accuracy of pulse oximetry.
- Steeve Giguère, L Chris Sanchez, and Andre Shih.
- Department of Large Animal Medicine, College of Veterinary Medicine, University of Georgia, Athens, GA 30602.
- J Vet Emerg Crit Care (San Antonio). 2014 Sep 1; 24 (5): 529-35.
ObjectivesTo (1) assess the agreement between calculated values for arterial hemoglobin saturation of oxygen (SaO2 ) and values obtained by co-oximetry, (2) assess the accuracy of 2 pulse oximetry monitors for measurement of SaO2 in foals, and for each monitor, and (3) determine the optimal combination of sensor type and site of sensor placement for SaO2 monitoring.DesignProspective experimental study.SettingUniversity teaching hospital.AnimalsSix neonatal foals.InterventionsFoals were anesthetized with isoflurane and SaO2 was manipulated by varying the inspired fraction of oxygen. SaO2 was calculated from oxygen tension or measured by pulse oximetry using 2 monitors equipped with transmission or reflectance sensors attached to the foal's tongue, lip, ear, or inserted rectally (reflectance sensor only). SaO2 values measured by co-oximetry were used as the gold standard to calculate bias.Measurements And Main ResultsMean (±SD) SaO2 determined by co-oximetry was 65.2% ± 11.8%, 85.4% ± 2.5%, and 97.2% ± 0.4% at the low, intermediate, and high SaO2 level, respectively. Sensors attached to the ear failed to provide SaO2 readings for most attempts. Reflectance sensors placed on the lip or rectally gave significantly larger biases at low SaO2 (-17.0% and -23.6%, respectively) than at higher levels. Bias of all other combinations of monitors, sensors, and sites (-1.8 to -4.1%) was not significantly influenced by the level of SaO2 or different from each other. The bias of calculated saturation was similar to that of pulse oximetry.ConclusionsTransmission sensors placed on the lip or tongue or reflectance sensors placed on the tongue give the most accurate assessment of SaO2 in anesthetized neonatal foals. Calculated saturation is not more accurate than pulse oximetry to estimate SaO2 .© Veterinary Emergency and Critical Care Society 2014.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.