• Spine · May 2006

    Measurement error of lumbar total disc replacement range of motion.

    • Moe R Lim, Randall T Loder, Russel C Huang, Stephen Lyman, Kai Zhang, Andrew Sama, Elias C Papadopoulos, Kristin Warner, Federico P Girardi, and Frank P Cammisa.
    • Department of Orthopaedic Surgery, University of North Carolina-Chapel Hill, Chapel Hill, NC 27599-705, USA. Moe_Lim@med.unc.edu
    • Spine. 2006 May 1; 31 (10): E291-7.

    Study DesignA retrospective review of lumbar total disc replacement (TDR) radiographs.ObjectiveTo determine the error and variability in measuring TDR radiographic range of motion (ROM).Summary Of Background DataMotion preservation is the driving force behind lumbar TDR technology. In the recent literature, sagittal radiographic TDR ROM as low as 2 degrees has been reported. In these studies, ROM was determined by using the Cobb method to measure TDR sagittal alignment angles in flexion-extension lateral radiographs. However, previous studies in the spinal deformity literature have shown that the Cobb method is very susceptible to measurement error.MethodsThere were 5 observers, including 2 attending orthopedic spine surgeons, 1 spine fellow, 1 fifth-year resident, and 1 fourth-year resident, who measured the ROM of 50 ProDisc II (Synthes Spine Solutions, New York, NY) TDRs on standard flexion-extension lumbar spine radiograph sets. Repeated measurements were made on 2 occasions using the Cobb method. Measurement variability was calculated using 3 statistical methods.ResultsThe 3 statistical methods resulted in extremely similar values for TDR ROM observer variability. Overall, the intraobserver variability of TDR ROM measurement was +/-4.6 degrees, and interobserver variability was +/-5.2 degrees .ConclusionsTo be 95% certain that an implanted TDR prosthesis has any sagittal motion, a ROM of at least 4.6 degrees must be observed, which is the upper limit of intraobserver measurement variability for a TDR with a true ROM of 0 degrees. To be 95% certain that a change in TDR ROM has occurred between 2 measurements by the same observer, a change in ROM of at least 9.6 degrees must be observed (the entire range of +/-4.6 degrees intraobserver variability). ROM measurement variability should be considered when evaluating the success or failure of motion preservation in lumbar TDR.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…