• J Clin Monit Comput · Dec 2015

    Comparative Study Observational Study

    Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning.

    • Youcef Guechi, Amélie Pichot, Denis Frasca, Fatima Rayeh-Pelardy, Jean-Yves Lardeur, and Olivier Mimoz.
    • Emergency Department, University Hospital of Poitiers, 2 rue de la Milétrie, 86000, Poitiers, France.
    • J Clin Monit Comput. 2015 Dec 1; 29 (6): 721-6.

    AbstractTo compare respiration rate measurement by an acoustic method and thoracic impedance to capnometry as the reference method, in patients at the Emergency Department after drug or alcoholic poisoning. In this observational study, 30 patients aged 18 or older, hospitalized at the Emergency Department for drug or alcoholic poisoning, without any contraindication to a face mask and/or a cervical acoustic sensor, were included in the study. They benefited from a simultaneous recording of their respiration rate by the acoustic method (RRa(®), Masimo Corp., Irvine, CA, USA), by thoracic impedance (Philips Intellivue(®) MP2, Suresnes, France) and by capnometry (Capnostream(®) 20, Oridion, Jerusalem, Israël) through a face mask (Capnomask(®), Mediplus Ltd, Raleigh, NC, USA) for 40-60 min. Of the 86,578 triplets collected, 77,155 (89.1%) were exploitable. Median (range) respiration rate measured by capnometry was 18 (7-29) bpm. Compared to capnometry, bias and limits of agreement were 0.1 ± 3.8 bpm for the acoustic method and 0.3 ± 5.5 bpm for thoracic impedance. The proportions of RR values collected by acoustic method or by thoracic impedance which differed over 10 or 20% during more than 15 s, compared to capnometry, were 8.3 versus 14.3, and 1.5 versus 3.8%, respectively (p < 0.0001). The acoustic sensor had to be repositioned on three patients. For 11 patients, the Capnomask(®) was removed several times. In patients with drug or alcoholic poisoning, the acoustic method seems more accurate than thoracic impedance and better tolerated than face mask capnometry.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.