    BackgroundNon-invasive continous monitoring of finger arterial pressure has gained increasing interest. The aim of the present study was to compare the accuracy of non-invasive reconstructed brachial artery pressure by the Nexfin™ device (NFAP) with invasive femoral (IFAP) and radial (IRAP) artery pressure before and after cardiopulmonary bypass (CPB).MethodsFifty patients scheduled for elective coronary surgery were studied before and after CPB, respectively. Each patient was monitored with the non-invasive system, and both an indwelling femoral and radial arterial catheter. A passive leg raising maneuver was also performed before and after CPB. Measurements included mean (MAP), systolic (SAP) and diastolic (DAP) arterial pressure by NFAP (MAP,SAP,DAP(NFAP)), IFAP (MAP,SAP,DAP(IFAP)) and IRAP (MAP,SAP,DAP(IRAP)). Percentage changes of MAP for all measurement sites were also calculated.ResultsThere was a moderate correlation between MAP(NFAP) and MAP(IFAP) both before (r=0.64, P<0.0001) and after (r=0.57, P<0.0001) CPB, with a percentage error (PE) of 29% and 27%, respectively. Correlation coefficients between MAP(NFAP) and MAP(IRAP) were r=0.53, P<0.0001 (PE 34%) before and r=0.54, P<0.0001 (PE 29%) after CPB. There was a significant correlation in percentage changes between ∆MAP(NFAP) and ∆MAP(IFAP) before (r=0.70, P<0.0001) and after (r=0.71, P<0.0001) CPB and for ∆MAP(NFAP) and ∆MAP(IRAP) (r=0.67, P<0.0001; r=0.74, P<0.0001), respectively.ConclusionNon-invasive, reconstructed brachial artery pressure showed moderate correlation compared with both invasive femoral and radial artery pressure. Furthermore, the non-invasive monitoring system was able to reflect percentage changes in mean arterial pressure in a moderate fashion.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…