-
Acta Anaesthesiol Scand · Aug 2003
Comparative StudyComparison of transcutaneous and endtidal CO2-monitoring for rigid bronchoscopy during high-frequency jet ventilation.
- M Simon, R Gottschall, M Gugel, H Fritz, S Mohr, and U Klein.
- Department of Anesthesiology and Intensive Care Medicine, University Hospital Jena, Germany. mark.simon@med.uni-jena.de
- Acta Anaesthesiol Scand. 2003 Aug 1; 47 (7): 861-7.
ObjectiveTo compare endtidal and transcutaneous respiratory monitoring of high-frequency jet ventilation (HFJV) in rigid bronchoscopy. Both techniques provide a noninvasive measurement of pCO2.MethodsHigh-frequency jet ventilation was applied via a rigid bronchoscope. Driving pressure (DP) was initially adapted to ensure normal ventilation. It was then changed twice by +/- 30% from the initial value. Endtidal and transcutaneous data were compared with arterial blood gas monitoring (ABG).ResultsResults were analyzed separately for the time just after changing the driving pressure (10 min) and the remaining time until the next change of the driving pressure (4 min). The first part was called the dynamic phase, and the second part the steady-state phase. Correlation coefficient between endtidal capnography and ABG was 0.96 for the steady state and 0.94 for the dynamic phase, respectively. Bland-Altman analysis revealed a bias of -0.21 kPa with limits of agreement (LOA) 1.63 kPa for the steady state and -0.25 kPa, 2.08 kPa for the dynamic phase, respectively. Correlation coefficient between transcutaneous monitoring and ABG for the steady state phase was 0.83, and was 0.72 for the dynamic phase. Bland-Altman analysis resulted in a bias of -0.89 kPa with LOA - 3.84 kPa during steady state and 0.92 kPa, 4.06 kPa for the dynamic phase, respectively.ConclusionEndtidal capnography offers accurate respiratory monitoring of HFJV. Transcutaneous monitoring showed a good correlation to ABG only during steady-state conditions. For the dynamic phase the accuracy was significantly lower. Thus, we cannot recommend transcutaneous respiratory monitoring for the specific indication of rigid bronchoscopy using HFJV.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.