-
J Spinal Disord Tech · Feb 2010
Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws.
- Hassan Alosh, Scott L Parker, Matthew J McGirt, Ziya L Gokaslan, Timothy F Witham, Ali Bydon, Jean-Paul Wolinsky, and Daniel M Sciubba.
- Department of Neurosurgery, Johns Hopkins School of Medicine, Baltimore, MD, USA.
- J Spinal Disord Tech. 2010 Feb 1; 23 (1): 9-14.
Study DesignA retrospective review study.ObjectiveIn this study, we attempt to identify radiographic variables associated with likelihood of intraoperative breach during C2 pedicle screw placement. In addition, we attempt to correlate surgeon experience with breach rate.Summary Of Background DataPedicle screws have emerged as an effective approach for obtaining fixation of the axis, yet placement of C2 pedicle screws is technically demanding and poses the risk of injury to the vertebral artery. Given the evidence for substantial variation in C2 anatomy, preoperative assessment of computed tomography (CT) scans may indicate, which patients are at increased risk for cortical breach during the pedicle screw placement.Materials And MethodsA retrospective review of all patients undergoing C2 pedicle screw fixation at a single institution over the last 6 years was conducted. Radiographic cortical breaches were defined on postoperative CT scans as visualization of the screw beyond the cortical edge. Radiographic measurements were determined from preoperative CT scans and were then correlated with breaches via Student t test. The association of breach rate with surgeon experience was evaluated using univariate linear regression.ResultsNinety-three patients underwent placement of 170 screws. Cortical breach was detected on postoperative CT scans in 43 screws (25.3%). One clinically significant breach occurred with damage to the left vertebral artery intraoperatively. On axial CT sections, mean pedicle isthmus diameter was significantly smaller in patients with breach than in patients without breach for both left and right sides, P=0.006 and P=0.010, respectively. Specifically, a diameter of less than 6 mm was associated with a nearly 2-fold increase in risk of cortical breach (37% vs. 21%). Surgeons with greater experience in placing C2 pedicle screws were noted to have a lower breach incidence (P=0.004).ConclusionsDuring placement of C2 pedicle screws, likelihood of cortical breach may be associated with size of pedicle and surgeon experience. Extensive preoperative evaluation of CT scans and consideration of technical demands of procedure may help avoid complications with such internal fixation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.