-
Minerva anestesiologica · Mar 2013
Comparative StudyCardiopulmonary resuscitation performance during simulator-based trainings: a comparative retrospective analysis of adherence to 2005 and 2010 guidelines.
- V Mayer, C M Schulz, M Kreuzer, K J Wagner, G Schneider, and E F Kochs.
- Department of Anesthesiology, Klinikum rechts der Isar, Technische Universität München, München, Germany.
- Minerva Anestesiol. 2013 Mar 1;79(3):264-73.
BackgroundNew cardiopulmonary resuscitation (CPR) guidelines have been published in 2010 emphasizing the importance of minimizing interruptions during chest compression. The aim of our study was to compare the simulator-based CPR training performance of physicians not specialized in anaesthesia and intensive care nurses before and after implementation of new resuscitation guidelines.MethodsIn autumn 2010, a total of 74 scenarios during six 1.5 day simulation-based CPR trainings were performed. Four of them were conducted after the implementation of the 2010 guidelines. During each simulated scenario a programmed script standardized the conditions of the simulator and its reactions on the trainees' actions. CPR relevant parameters were extracted on the basis of the simulator's log files and no-flow-time fraction and median cardiac output of the simulator were calculated. Results before and after the guideline implementation were compared using the Wilcoxon Two Sample Test.ResultsThirty-four out of 74 scenarios were included into the analysis. During training according to the 2010 guidelines, the no-flow-time fraction was lower (median: 21.8% [IQR: 16.1-27.1%] vs. 29.1 % [IQR: 25.0-30.9 %]; P=0.04). The median cardiac output increased from 1.60 L/min-1 [IQR: 1.50-1.65 L/min-1] to 1.90 L/min-1 [IQR: 1.80-2.10 L/min-1]; P<0.001) when the CPR training was conducted according to the 2010 resuscitation guidelines.ConclusionNon-anesthesiological physicians and intensive care nurses training demonstrated an improved CPR performance in a high-fidelity human patient simulator with respect to the median cardiac output and duration of no-flow-time when 2010 CPR guidelines were applied.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.