J. Am. Coll. Cardiol. · Jul 2012
Randomized Controlled Trial Multicenter Study Comparative StudySecond-generation everolimus-eluting stents versus first-generation sirolimus-eluting stents in acute myocardial infarction. 1-year results of the randomized XAMI (XienceV Stent vs. Cypher Stent in Primary PCI for Acute Myocardial Infarction) trial.
- Sjoerd H Hofma, Jan Brouwer, Matthijs A Velders, Arnoud W J van't Hof, Pieter C Smits, Michel Queré, Cornelis Jan de Vries, and Adrianus J van Boven.
- Medical Center Leeuwarden,Henri Dunantweg 2, Leeuwarden, the Netherlands. s.h.hofma@znb.nl
- J. Am. Coll. Cardiol. 2012 Jul 31; 60 (5): 381-7.
ObjectivesThe goal of this study was to compare the efficacy and safety of second-generation everolimus-eluting stents (EES) with first-generation sirolimus-eluting stents (SES) in primary percutaneous coronary intervention (PCI) for acute myocardial infarction (AMI).BackgroundDrug-eluting stents (DES) in AMI are still feared for possible late and very late stent thrombosis (ST). Newer-generation DES, with more hemocompatible polymers and improved healing, may show promise regarding increased efficacy of DES with improved safety. However, no randomized trials in AMI are available.MethodsA total of 625 patients with AMI were randomized (2:1) to receive EES or SES in the XAMI (XienceV Stent vs Cypher Stent in Primary PCI for Acute Myocardial Infarction) trial. Primary endpoint was major adverse cardiac events (MACE) at 1 year consisting of cardiac death, nonfatal AMI, or any target vessel revascularization. The study was powered for noninferiority of EES. Secondary endpoints comprised ST rates and MACE rate up to 3 years.ResultsThe MACE rate was 4.0% for EES and 7.7% for SES; the absolute difference was -3.7% (95% confidence interval: -8.28 to -0.03; p = 0.048) and relative risk was 0.52 (95% confidence interval: 0.27 to 1.00). One-year cardiac mortality was low at 1.5% for EES versus 2.7% for SES (p = 0.36), and 1-year incidence of definite and/or probable ST was 1.2% for EES versus 2.7% for SES (p = 0.21).ConclusionsIn this all-comer, randomized, multicenter AMI trial, second-generation EES was noninferior to SES, and superiority for MACE was suggested. ST rate in EES at 1-year was low, but long-term follow-up and larger studies will have to show whether very late ST rates will also be improved in newer DES. (XienceV Stent vs Cypher Stent in Primary PCI for Acute Myocardial Infarction [XAMI]; NTR1123).Copyright © 2012 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.