• Respiration · Jan 1986

    Airway resistance measurements throughout the respiratory cycle in infants.

    • C S Beardsmore, S Godfrey, N Shani, C Maayan, and E Bar-Yishay.
    • Respiration. 1986 Jan 1; 49 (2): 81-93.

    AbstractUsing a constant-volume infant whole-body plethysmograph containing a heated rebreathing bag, we have been able to measure airway resistance (Raw) throughout the respiratory cycle using a computer-based technique. Data from the plethysmograph transducers are sampled at 60 Hz for the calculations and Raw is calculated at each point sampled during the breath, with appropriate corrections for absolute lung volume. It was found that in most cases Raw varied less with respect to tidal volume than to tidal flow. Various patterns of Raw change in relation to tidal volume were found. These included an elevated but relatively constant resistance, a progressively rising expiratory resistance, and in 3 infants with laryngomalacia, a progressively rising inspiratory resistance. It was also found that the dynamic performance of the rebreathing bag was such that considerable errors would occur if apparatus resistance was assumed to be constant and so the actual apparatus resistance at each point was subtracted from the total resistance to give Raw. In conclusion, Raw is not constant throughout the respiratory cycle in infants and the pattern of change conveys additional information.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.